PRODUCTS
VR
  • Product Details
  • Product Applications


Reliable Power · Anywhere · Anytime

ZIQI Industrial Diesel Generator Set

10 kVA to 3000 kVA · Cummins / Perkins / Yuchai Engines · Open & Silent Type
3000
kVA Max Power
Full Range
50°C
Ambient Rating
Tropical Ready
≤65
dB(A) Silent Type
Low Noise
4
Engine Brands
Cummins · Perkins · Yuchai · Weichai

Why Choose ZIQI Diesel Generators?

ZIQI offers premium industrial power solutions ranging from 10 kVA to 3000 kVA. Powered by world-class engines — Cummins, Perkins, Yuchai, and Weichai — paired with Stamford / Leroy Somer 100% copper-wound alternators and DeepSea / SmartGen digital controllers. Available in Open Type (for engine rooms with maximum ventilation) and Silent Type (for noise-sensitive areas down to 65 dB). Every unit is factory-tested at full load, rated for 50°C tropical ambient, and shipped ready to connect. From hospital backup to mining camp prime power — ZIQI generators keep your operations running.

Where Are Diesel Generators Used?
From emergency backup to continuous prime power — ZIQI generators cover every scenario.
🏥
Emergency Backup Power

Essential for hospitals, data centers, telecom base stations, and financial institutions. When mains power fails, the generator starts instantly via ATS (Automatic Transfer Switch) to support critical loads — typically within 10-15 seconds.

🏗️
Construction & Work Sites

Provides flexible power for cranes, welders, mixers, and lighting towers where grid access is unstable or unavailable. Rugged design with reinforced base frame ensures durability in dusty and harsh environments.

⚡
Remote Area Prime Power

Serves as the primary power source for islands, mines, mountain villages, and oil fields. Capable of Continuous Power (COP) operation for 24/7 daily living and industrial production with unlimited running hours.

🎤
Events & Temporary Venues

Perfect for outdoor concerts, exhibitions, sports events, and wedding venues. Our Silent Type generators ensure low noise operation (≤65-75 dB at 7m) so they don't disturb the event or surrounding areas.

Not sure which generator size you need? Send us your load list — free sizing within 2 hours.

Get Free Sizing Quote            WhatsApp Us
Core Components
Every ZIQI generator is built from internationally proven subsystems.

System Breakdown

  • Diesel Engine: Cummins / Perkins / Yuchai / Weichai — water-cooled, turbocharged.

  • Alternator: Stamford / Leroy Somer — 100% copper winding, brushless, self-exciting.

  • Controller: DeepSea DSE6120 / SmartGen — digital display, remote monitoring capable.

  • Cooling System: 50°C rated radiator with tropical-grade coolant for harsh climates.

  • Base Frame: Heavy-duty steel with anti-vibration dampers & integrated fuel tank.

  • Circuit Breaker: ABB / Delixi — rated for generator output with short-circuit protection.

ZIQI Diesel Generator Structure Diagram — engine, alternator, controller, base frame layout
Power Rating Definitions
Understanding ESP, PRP, and COP helps you select the right generator for your application.
Generator Power Rating Graph showing ESP Standby, PRP Prime, and COP Continuous power curves
Emergency Standby (ESP)
Maximum power for utility failure backup. Limited to 500 hours/year with variable load. No overload permitted. Typical use: hospitals, data centers, office buildings.
Prime Rated (PRP)
Maximum power for unlimited hours at variable load. Allows 10% overload for 1 hour every 12 hours. Typical use: construction sites, remote operations.
Continuous Power (COP)
Maximum power for constant load, unlimited hours. Used as the sole power source. No overload. Typical use: island power, mining camps, off-grid facilities.
Range of Premium Products
Available in Open Type and Silent Type configurations to match your installation requirements.
Open Type vs Silent Type — Which Do You Need?
Both types use the same engine and alternator. The difference is the enclosure.
FeatureOpen TypeSilent Type
Noise Level (at 7m)85 – 100 dB(A)65 – 75 dB(A)
Best ForDedicated engine rooms, industrial plantsResidential, hospitals, offices, events
Weather ProtectionRequires building or shelterFully weatherproof canopy — outdoor OK
Maintenance AccessFully exposed — easy 360° accessSide doors — slightly more effort
FootprintSmaller (no canopy)10-15% larger due to enclosure
CostLower — no canopy cost10-20% premium for soundproof housing
TransportLighter, easier to moveHeavier but includes lifting points
Engine Brand Comparison
ZIQI offers multiple engine brands to match your budget and project requirements.
CriteriaCummins (USA)Perkins (UK)Yuchai (China)Weichai (China)
Power Range20 – 3000 kVA10 – 2500 kVA20 – 2000 kVA20 – 1500 kVA
Global Parts Network190+ countries170+ countriesAsia / Africa / S. AmericaAsia / Africa
Fuel Efficiency★★★★★★★★★★★★★★★★★★
Durability / Overhaul Interval20,000 – 30,000 hrs15,000 – 25,000 hrs12,000 – 20,000 hrs10,000 – 18,000 hrs
Price Level$$$$$$$$$$$$
Best ForCritical facilities, exportTelecom, commercialCost-effective projectsBudget-friendly, domestic

Need a Diesel Generator Quote?

Tell us your required kVA, voltage, frequency, and whether you need Open or Silent Type. We'll respond with a full technical proposal within 24 hours.

Frequently Asked Questions
What is the difference between Prime (PRP) and Standby (ESP) power?
Prime Power (PRP) is for unlimited running hours at variable load, with 10% overload allowed for 1 hour every 12 hours. Standby Power (ESP) is the maximum output during a utility failure — limited to 500 hours per year, no overload. Choose ESP for backup; choose PRP for continuous or semi-continuous use like construction or remote areas.
What is the difference between Open Type and Silent Type generators?
Both use the same engine and alternator. Open Type has no enclosure — ideal for dedicated engine rooms with existing ventilation. Silent Type adds a soundproof canopy that reduces noise from 85-100 dB to 65-75 dB(A) at 7 meters, making it suitable for residential areas, hospitals, offices, and outdoor events. The Silent Type costs about 10-20% more.
What is the difference between Cummins and Yuchai engines?
Cummins (USA) offers top-tier durability, worldwide parts availability in 190+ countries, and overhaul intervals of 20,000-30,000 hours — ideal for critical facilities and export projects. Yuchai (China) delivers excellent heavy-duty performance with overhaul intervals of 12,000-20,000 hours at a significantly lower price point — ideal for cost-sensitive domestic and regional projects. Both are proven in generator applications.
How do I calculate what size generator I need?
Add up the wattage (kW) of all equipment running simultaneously. For motor loads, account for starting current which can be 3-6× the running current — this is the most common sizing mistake. Multiply your total by 1.25 for a safety margin. Example: 200 kW total load → select at least 250 kVA rated generator. Not sure? Send us your equipment list and we'll calculate the optimal model for free.
Does the generator come with a fuel tank?
Yes. Generators under 1000 kVA typically include a base-mounted fuel tank capable of running 8 hours at full load. Larger units above 1000 kVA may require an external bulk fuel tank, which ZIQI can supply as an option. Daily fuel tank capacity can also be customized at order time.
Can ZIQI generators run on both 50 Hz and 60 Hz?
Each generator is factory-configured for either 50 Hz (1500 RPM) or 60 Hz (1800 RPM). Specify your required frequency when ordering. ZIQI supports both standards and can customize voltage output — 230V, 400V, 480V, or other configurations — to match your local grid requirements.
What is an ATS (Automatic Transfer Switch)?
An ATS monitors the mains power supply. When it detects a failure, it automatically signals the generator to start and transfers the load from mains to generator — typically within 10-15 seconds. When mains power returns, the ATS transfers back and shuts down the generator. ZIQI supplies ATS panels as a standard option for all standby installations.
What maintenance does a diesel generator require?
Routine maintenance includes: oil and filter change every 250-500 hours, fuel filter every 500 hours, air filter inspection every 500 hours, coolant check every 1000 hours. For standby generators that rarely run, perform a monthly 30-minute test run at 50%+ load to keep the engine healthy. ZIQI provides a complete maintenance schedule with every unit.
Related Products

* Specifications subject to change without notice. All generators are factory-tested at full load before shipping. Voltage, frequency, and enclosure type customizable at order. Contact ZIQI for your project requirements.


Basic Information
  • Year Established
    --
  • Business Type
    --
  • Country / Region
    --
  • Main Industry
    --
  • Main Products
    --
  • Enterprise Legal Person
    --
  • Total Employees
    --
  • Annual Output Value
    --
  • Export Market
    --
  • Cooperated Customers
    --
Weifang Ricardo Full Range 50Hz
Genset ModelGenset Output (50Hz)Diesel Engine SpecificationsDimension (L×W×H) mm
PrimeStandbyEngine ModelCyl.Bore×Stroke
(mm)
Disp.
(L)
AspirationVoltage
(V)
Open TypeSilent Type
kWkVAkWkVA
GD-22R16201822490D490×952.42Natural12V1600×730×11002000×900×1200
GD-28R20252228ZH4102D4102×1153.76Natural12V1600×730×11002000×900×1200
GD-33R24302633ZH4102D4102×1153.76Natural12V1600×730×11002000×900×1200
GD-41R30383341ZH4102D4102×1153.76Natural12V1700×800×11002100×900×1200
GD-55R40504455ZH4102ZD4102×1153.76Turbocharged-1700×800×11002150×900×1200
GD-70R50635569ZH4105ZD4105×1153.98Turbocharged24V1700×800×11002150×900×1200
GD-70R (Alt)50635569R4105ZD4105×1254.33Turbocharged24V1850×800×11502300×1000×1300
GD-83R60756683R4105ZLD4105×1304.33Turbo & Inter-cooled24V1850×800×11502400×1000×1300
GD-100R729080100R4105ZLD4108×1354.5Turbo & Inter-cooled24V1850×800×12002400×1000×1300
GD-110R8010088110R6105AZD6105×1357.1Turbocharged24V2320×900×12502600×1130×1550
GD-140R100125110138R6105AZLD6105×1357.1Turbo & Inter-cooled24V2320×900×12502730×1100×1450
GD-165R120150132165R6105IZLD6105×1357.1Turbo & Inter-cooled24V2320×900×12502730×1100×1450
GD-210R150188165206R6108ZLD6108×1357.41Turbo & Inter-cooled24V2450×900×12502950×1100×1650
GD-275R200250220275P10ZLD6126×1309.72Turbo & Inter-cooled24V2850×1000×16503400×1150×1870
GD-345R250313275344618ZLD6126×15511.596Turbo & Inter-cooled24V3000×1050×18003700×1400×2100
GD-385R300375330413P12ZLD6126×15511.596Turbo & Inter-cooled24V3000×1050×18003700×1400×2100
GD-481R350438385481P12ZLD6126×15511.596Turbo & Inter-cooled24V3300×1200×19003950×1600×2200
GD-550R400500440550P13Q6127×16512.54Turbo & Inter-cooled24V3300×1200×19003950×1600×2200

Recommended

Send your inquiry

GET IN TOUCH WITH US

Just leave your email or phone number on the contact form so we can serve you.

Chat
Now

Send your inquiry

Choose a different language
╳
العربية
Беларуская
Deutsch
Ελληνικά
English
Español
français
Magyar
italiano
Nederlands
Português
русский
Current language:English