ZIQI Compressor Group · Updated July 2026
Shanghai Art Printing Co., Ltd. operated a mixed-brand compressed air system — one ZIQI GAT-55A fixed-speed two-stage unit plus three other-brand 55kW single-stage compressors (one held as standby) — that could no longer meet growing plant air demand. ZIQI replaced two of the other-brand 55kW single-stage units with two GAT-55ACF two-stage VSD compressors, added an LK-55/4 control cabinet for multi-unit sequencing, and retrofitted the site's compressed air piping to aluminum. The completed project delivered a verified 288,300 kWh/year reduction in electricity consumption, driven by the combined effect of two-stage compression efficiency and VSD demand-matching.
Before the retrofit, Shanghai Art Printing's compressor room ran a mixed fleet: one ZIQI GAT-55A fixed-speed two-stage compressor operating alongside three 55kW single-stage units from other manufacturers, with one of those single-stage machines held in reserve as a standby. As the plant's printing production volume increased, total compressed air consumption began to outpace what this configuration could reliably deliver — a common failure pattern in facilities that have added machinery over time without re-evaluating total system capacity and efficiency.
After assessing the plant's actual compressed air demand profile, ZIQI's engineering team proposed replacing two of the existing other-brand 55kW single-stage compressors with two GAT-55ACF two-stage VSD units — matching the original 55kW power rating while fundamentally changing the compression architecture.
Photos taken after the completed retrofit at the customer's facility:
Compressor room after installation of the GAT-55ACF two-stage VSD units and LK-55/4 control cabinet.
Aluminum compressed air distribution piping installed during the site retrofit.Following completion of the retrofit, the plant recorded a reduction in compressed air system electricity consumption of approximately 288,300 kWh per year. This result reflects the combined effect of two mechanisms operating together: the inherent specific power advantage of two-stage compression over single-stage compression at the same discharge pressure, and the VSD's ability to continuously match motor speed to the plant's actual real-time air demand rather than cycling through fixed-speed load/unload states.
| System Configuration | Detail |
|---|---|
| Before Retrofit | 1 × ZIQI GAT-55A (fixed-speed two-stage) + 3 × other-brand 55kW single-stage units (1 as standby) |
| After Retrofit | 1 × ZIQI GAT-55A + 2 × ZIQI GAT-55ACF (two-stage VSD) + 1 × other-brand unit (standby) + LK-55/4 control cabinet |
| Verified Annual Savings | 288,300 kWh/year |
For a full technical breakdown of how two-stage compression architecture reduces specific power consumption, see our GAT two-stage series guide. For VSD-specific energy savings mechanics and payback calculations, see our VSD sizing and ROI guide.
Running a mixed-brand or aging compressor fleet? ZIQI's engineering team can assess your facility's actual demand profile and calculate potential energy savings from a two-stage VSD retrofit.