ENERGY SAVING CASES
VR

Shanghai Art Printing Plant: GAT-55ACF Two- Stage VSD Compressor Retrofit Saves 288,300 kWh/Year

Shanghai Art Printing Plant: GAT-55ACF Two-Stage VSD Compressor Retrofit Saves 288,300 kWh/Year
Marin Hu
Marin Hu

Compressed Air Systems Engineer

ZIQI Compressor Group · Updated July 2026

19 Years Experience                60+ Export Markets                GHH-RAND Certified                Energy Retrofit Specialist

Shanghai Art Printing Plant: GAT-55ACF Two-Stage VSD Compressor Retrofit Case Study

288,300 kWh            Verified Annual Energy Savings
2 Units            GAT-55ACF Two-Stage VSD Installed
55kW            Direct Power Rating Match
100%            Aluminum Piping Retrofit
QUICK ANSWER — SHANGHAI PRINTING PLANT ENERGY RETROFIT

Shanghai Art Printing Co., Ltd. operated a mixed-brand compressed air system — one ZIQI GAT-55A fixed-speed two-stage unit plus three other-brand 55kW single-stage compressors (one held as standby) — that could no longer meet growing plant air demand. ZIQI replaced two of the other-brand 55kW single-stage units with two GAT-55ACF two-stage VSD compressors, added an LK-55/4 control cabinet for multi-unit sequencing, and retrofitted the site's compressed air piping to aluminum. The completed project delivered a verified 288,300 kWh/year reduction in electricity consumption, driven by the combined effect of two-stage compression efficiency and VSD demand-matching.

The Problem: Mixed-Brand Single-Stage Fleet Running Out of Capacity

Before the retrofit, Shanghai Art Printing's compressor room ran a mixed fleet: one ZIQI GAT-55A fixed-speed two-stage compressor operating alongside three 55kW single-stage units from other manufacturers, with one of those single-stage machines held in reserve as a standby. As the plant's printing production volume increased, total compressed air consumption began to outpace what this configuration could reliably deliver — a common failure pattern in facilities that have added machinery over time without re-evaluating total system capacity and efficiency.

The Solution: Two GAT-55ACF Two-Stage VSD Units + Control Integration

After assessing the plant's actual compressed air demand profile, ZIQI's engineering team proposed replacing two of the existing other-brand 55kW single-stage compressors with two GAT-55ACF two-stage VSD units — matching the original 55kW power rating while fundamentally changing the compression architecture.

Retrofit Scope of Work

1
Install 2 × GAT-55ACF Two-Stage VSD Compressors
               Two-stage compression with interstage cooling reduces specific power consumption compared to single-stage compression at the same discharge pressure, while the integrated VSD continuously matches motor speed to real-time plant air demand — eliminating the load/unload idling losses inherent to the fixed-speed single-stage units being replaced.
2
Add LK-55/4 Control Cabinet
               A dedicated control cabinet was installed to sequence and coordinate operation across the multi-compressor fleet, ensuring the existing GAT-55A fixed-speed unit and the two new GAT-55ACF VSD units work together efficiently rather than competing for load independently.
3
Retain 1 Other-Brand Unit as Backup
               Rather than fully removing the original equipment, one remaining other-brand compressor was kept on-site as a standby machine, preserving redundancy for the plant while the new two-stage VSD units handle normal production load.
4
Retrofit Site Piping to Aluminum
               Select sections of the plant's compressed air distribution piping were replaced with aluminum piping, reducing internal corrosion risk and pressure drop compared to the legacy piping being replaced.

On-Site Results

Photos taken after the completed retrofit at the customer's facility:

Shanghai Art Printing compressor room after GAT-55ACF two-stage VSD retrofit    Compressor room after installation of the GAT-55ACF two-stage VSD units and LK-55/4 control cabinet.    Aluminum compressed air piping installed at Shanghai Art Printing during the retrofit    Aluminum compressed air distribution piping installed during the site retrofit.

Verified Energy Savings

Following completion of the retrofit, the plant recorded a reduction in compressed air system electricity consumption of approximately 288,300 kWh per year. This result reflects the combined effect of two mechanisms operating together: the inherent specific power advantage of two-stage compression over single-stage compression at the same discharge pressure, and the VSD's ability to continuously match motor speed to the plant's actual real-time air demand rather than cycling through fixed-speed load/unload states.

System ConfigurationDetail
Before Retrofit1 × ZIQI GAT-55A (fixed-speed two-stage) + 3 × other-brand 55kW single-stage units (1 as standby)
After Retrofit1 × ZIQI GAT-55A + 2 × ZIQI GAT-55ACF (two-stage VSD) + 1 × other-brand unit (standby) + LK-55/4 control cabinet
Verified Annual Savings288,300 kWh/year

For a full technical breakdown of how two-stage compression architecture reduces specific power consumption, see our GAT two-stage series guide. For VSD-specific energy savings mechanics and payback calculations, see our VSD sizing and ROI guide.

Frequently Asked Questions

Why did replacing single-stage compressors with two-stage VSD units save energy?
Two-stage compression splits the compression ratio across two stages with interstage cooling, which reduces specific power consumption (kW per m³/min) compared to single-stage compression at the same discharge pressure. Adding VSD on top of this eliminates the load/unload idling losses that fixed-speed single-stage compressors incur when air demand fluctuates, compounding the savings.
What is the GAT-55ACF model?
GAT-55ACF is a 55kW two-stage rotary screw air compressor from ZIQI's GAT series, equipped with a Variable Speed Drive (VSD) for continuous speed modulation. It combines the specific-power efficiency advantage of two-stage compression with VSD's ability to match motor output to real-time demand.
Why keep an old compressor as a backup instead of removing it entirely?
Retaining a standby unit preserves system redundancy in case of maintenance downtime or unexpected demand spikes, without requiring the customer to fully replace their entire compressed air fleet in a single retrofit. This is a common phased-transition approach for facilities upgrading their compressed air infrastructure.
Why was the compressed air piping upgraded to aluminum during the retrofit?
Aluminum compressed air piping resists internal corrosion better than legacy carbon steel piping and typically has a smoother internal bore, reducing pressure drop across the distribution network. Combined with the new compressor installation, this helps ensure the energy savings generated at the compressor are not lost to pipeline inefficiency downstream.

Related Technical Guides

Get a Compressed Air Energy Audit

Running a mixed-brand or aging compressor fleet? ZIQI's engineering team can assess your facility's actual demand profile and calculate potential energy savings from a two-stage VSD retrofit.

Basic Information
  • Year Established
    --
  • Business Type
    --
  • Country / Region
    --
  • Main Industry
    --
  • Main Products
    --
  • Enterprise Legal Person
    --
  • Total Employees
    --
  • Annual Output Value
    --
  • Export Market
    --
  • Cooperated Customers
    --
Chat
Now

Send your inquiry

Choose a different language
╳
العربية
Беларуская
Deutsch
Ελληνικά
English
Español
français
Magyar
italiano
Nederlands
Português
русский
Current language:English