How to design a complete compressed air system before you request a factory-direct quote: compressor flow and pressure, receiver tank storage, air treatment, distribution piping and the leaks that quietly drain your power budget.
Published by ZIQI Compressor Group, which manufactures the products discussed in this guide.
1–3 Gal/CFM
rotary screw receiver sizing rule (wet tank)
Source: ZIQI Air Receiver Tank Sizing Guide
+3°C
general-manufacturing pressure dew point, ISO 8573-1 Class 4
Source: ZIQI Refrigerated vs Desiccant Air Dryer Guide
6–7 m/s
recommended main-line air velocity (CAGI / DOE guidance)
Source: CAGI piping practice (https://www.cagi.org/); U.S. DOE Compressed Air Tip Sheet #4 (https://www.energy.gov/sites/prod/files/2014/05/f16/compressed_air4.pdf)
<10%
max acceptable total pressure drop vs operating pressure
Source: U.S. DOE Compressed Air Tip Sheet #4 (https://www.energy.gov/sites/prod/files/2014/05/f16/compressed_air4.pdf)
A compressed air system is not one machine but a chain: a compressor that generates air, a receiver tank that stores it, a dryer and filter that clean it, piping that distributes it, and the tools or process that actually use it. ZIQI is a China-based air compressor manufacturer that ships complete systems to 200 export markets, and in quote enquiries the same gap appears again and again: each component is specified in isolation, then they fight each other on the factory floor. This design guide walks through the purchasing decisions in the order air flows, so the compressor, tank, dryer and piping are sized as one system rather than five separate guesses.
Every sizing decision downstream traces back to two numbers: the free air delivery (FAD) your plant needs, and the minimum pressure at which your tools or process will still run reliably. FAD is the actual volume of air delivered at the discharge, corrected to ambient inlet conditions, measured in cubic feet per minute (CFM) or cubic metres per minute (m³/min) — not the displacement figure stamped on the nameplate. Working pressure is the minimum acceptable pressure at the point of use, typically 7–8 bar (about 100–115 psi) for general pneumatic tools, with some processes running higher.
A variable speed drive (VSD) compressor matches motor speed to live demand, which both trims part-load energy use and reduces the receiver and dryer sizing margins you would otherwise need to cover load swings. For a first specification, fix the FAD and working pressure first; the tank, dryer and piping are all sized relative to those two values.
The receiver tank is the buffer that absorbs peak demand spikes and smooths the compressor's load/unload or modulation cycle. The required storage volume is calculated from how much air you need to draw down before the compressor can catch up:
Where the variables are defined as: V is the required air receiver tank volume, expressed in cubic feet (multiply V by 7.48 to convert to US gallons). Q is the excess peak demand flow requirement over compressor output capability, stated in cubic feet per minute (CFM). t is the allowed time duration for the pressure drawdown spike to occur without dropping below operational limits, stated in minutes. Pa is the standard atmospheric pressure constant, equivalent to 14.7 psia. P1 is the maximum system operating pressure threshold inside the tank, stated in absolute pressure (psig + 14.7). P2 is the minimum acceptable absolute pressure required to run downstream tooling reliably (psig + 14.7).
As a faster rules-of-thumb check, the receiver capacity per unit flow depends on compressor type and placement:
| Compressor type | Receiver capacity (wet tank, per CFM) | Source |
|---|---|---|
| Rotary screw | 1–3 gallons per CFM | ZIQI Air Receiver Tank Sizing Guide |
| Variable Speed Drive (VSD) | 2–4 gallons per CFM | ZIQI Air Receiver Tank Sizing Guide |
| Reciprocating (piston) | 3–6 gallons per CFM | ZIQI Air Receiver Tank Sizing Guide |
| Centrifugal | 0.5–1 gallon per CFM | ZIQI Air Receiver Tank Sizing Guide |
A reliable rule of thumb splits total facility storage into a 1/3 wet and 2/3 dry ratio: a wet tank upstream of the dryer drops out bulk liquid moisture and buffers pulsation, while the larger dry tank downstream stabilizes pressure for the distribution network. Applications with flat, continuous consumption can occasionally bypass the dry receiver, but the wet tank should always stay.
Moisture control is defined by pressure dew point (PDP): the temperature at which water vapor begins to condense at your operating pressure. The global reference is ISO 8573-1, which grades water content in classes. Pick the class from the process, then select the dryer technology to deliver it — never the reverse:

| Application scenario | Required pressure dew point | Recommended technology | Source |
|---|---|---|---|
| General manufacturing, machine tools, pneumatic tools | +3°C (ISO 8573-1 Class 4) | Refrigerated dryer | ZIQI Refrigerated vs Desiccant Air Dryer Guide |
| Food & beverage, secondary automated packaging | −20°C to −40°C (ISO Class 2–3) | Desiccant dryer | ZIQI Refrigerated vs Desiccant Air Dryer Guide |
| Pharmaceutical, semiconductor, outdoor winter lines | −40°C (ISO Class 2) | Desiccant dryer | ZIQI Refrigerated vs Desiccant Air Dryer Guide |
The dryer's rated capacity must be at least equal to your compressor's FAD at the working pressure. For heatless desiccant dryers, multiply the required downstream flow by a factor of 1.20, because 15–20% of the rated intake flow is consumed as purge air for regeneration and must not starve the plant. A refrigerated dryer alone extracts approximately 98% of the initial water in compressed air, which is why it covers the bulk of general manufacturing.
The distribution network is where most avoidable energy is lost. ZIQI's Aluminum Super Pipeline system combines aerospace-grade 6063-T5 aluminum alloy with a full-bore design that delivers clean air with negligible pressure drop across the run. The two numbers that decide pipe diameter are velocity and total pressure drop:

| Design parameter | Target | Upper limit | Source |
|---|---|---|---|
| Main-line air velocity | 6–7 m/s (≈20 ft/s) | 9 m/s (≈30 ft/s) | CAGI piping practice (https://www.cagi.org/); U.S. DOE Compressed Air Tip Sheet #4 (https://www.energy.gov/sites/prod/files/2014/05/f16/compressed_air4.pdf) |
| Total system pressure drop | ≈0.1 bar | <10% of operating pressure | U.S. DOE Compressed Air Tip Sheet #4 (https://www.energy.gov/sites/prod/files/2014/05/f16/compressed_air4.pdf) |
Exceeding the velocity ceiling raises turbulence and pressure drop; exceeding the pressure-drop ceiling forces the compressor to generate higher pressure just to deliver the same pressure at the tool. Because every 2 psi of avoidable pressure drop costs roughly 1% of compressor power, the piping diameter is a payback decision, not just a plumbing one.
Unchecked leaks typically waste 5–10% of total compressed air capacity in an industrial plant. Because leaks also force the compressor to run at higher pressure to compensate, they are one of the largest and most easily recovered energy drains in a compressed air system. A practical design habit is to size the compressor and piping for the required pressure plus a small margin, then patrol the network for leaks with an ultrasonic gun so the margin is not quietly consumed. Fixing leaks almost always costs less than adding compressor capacity to cover them.
Before you confirm an order, lock down the variables your supplier needs in one enquiry so the configuration is fixed before production starts:
| What to specify | Why it matters | Source |
|---|---|---|
| Required FAD and working pressure | Drives compressor, tank and dryer sizing | ZIQI system design practice |
| ISO 8573-1 dew point class | Decides refrigerated vs desiccant technology | ZIQI Refrigerated vs Desiccant Air Dryer Guide |
| Piping material and layout length | Sets velocity, pressure drop and install cost | CAGI / DOE piping guidance |
| Ambient conditions and voltage | Affects dryer choice and motor rating | ZIQI sales terms |
Send these together rather than piecemeal; a complete specification lets ZIQI engineers configure the full air treatment train and quote factory-direct, instead of shipping components that have to be re-sized after commissioning.
Send your flow, pressure, dew point class and piping layout — ZIQI engineers will configure the compressor, receiver, dryer and distribution as one train and quote factory-direct.