BLOG
VR

Two-Stage Screw Compressor Sizing Guide: 22-355kW, 6-13 Bar (GAT Series 2026)

Two-Stage Screw Compressor Sizing Guide: 22-355kW, 6-13 Bar (GAT Series 2026)
Marin Hu, Compressed Air Systems Engineer
Marin Hu

Compressed Air Systems Engineer

ZIQI Compressor Group · Updated July 2026

ZIQI · Est. 2007                200 Export Markets                Field Engineer                Two-Stage Compression Specialist

Two-Stage Screw Compressor Sizing Guide: 22-355kW Across 5 Pressure Options (GAT Series)

In continuous 24/7 heavy industrial facilities, electricity accounts for up to 80% of an air compressor's total lifecycle cost. When air demand is large or discharge pressure exceeds 8 bar, single-stage rotary screw compressors experience exponential heat and thermodynamic friction losses. As an established global air compressor manufacturer, ZIQI Compressor Group engineered the GAT Two-Stage Rotary Screw Series to divide compression into two intercooled stages, achieving near-isothermal compression efficiency. Sizing a two-stage machine requires matching total plant Free Air Delivery (FAD) across 5 standard pressure ratings (0.6, 0.7, 0.8, 1.0, and 1.3 MPa) while navigating cooling configurations (air-cooled vs. water-cooled) and optional Variable Frequency Control (VFC). This engineering guide details ZIQI's 17 verified GAT models spanning 22 kW to 355 kW.

22–355 kW            17 Models Available
0.6–1.3 MPa            5 Pressure Options (6-13 Bar)
Up to 15%            Energy Saving vs Single-Stage
100,000h            Airend Design Life
QUICK ANSWER — HOW TO SIZE A GAT TWO-STAGE COMPRESSOR

Sizing a GAT two-stage screw compressor requires evaluating required operating pressure (0.6, 0.7, 0.8, 1.0, or 1.3 MPa), total volumetric flow (4.20 to 73.00 m³/min), and plant heat rejection infrastructure. For medium baseloads from 22 kW to 132 kW, air-cooled models (GAT-22A to GAT-132A) offer turnkey installation. For heavy baseloads from 185 kW to 355 kW, water-cooled variants manage intensive heat loads. All GAT models feature 5:6 asymmetric rotor profiles, WEG IE4 IP55 motors, 1:1 direct flexible couplings, and interstage oil-injection cooling, cutting power consumption by up to 15% compared to single-stage units.

CHAPTER 1: THE PHYSICS OF TWO-STAGE COMPRESSION

Compressing atmospheric air to high pressure in a single rotor chamber generates intense heat. Per gas thermodynamic law ($PV^n = C$), higher compression ratios elevate air temperature, increasing internal air resistance and power demand.

ZIQI GAT two-stage compressors utilize twin tandem rotor sets housed within a heavy-duty cast iron body. Atmospheric air enters the primary low-pressure stage, where it is compressed to an intermediate pressure ratio (approx. 2.5:1). The air then passes through an integrated interstage fluid spray chamber, which absorbs thermal energy and drops the temperature significantly before the air enters the secondary high-pressure stage. To compare thermodynamic efficiency factors between designs, see our two-stage vs single-stage comparison.

Dual Mechanical & Operational Benefits:
  • Up to 15% Power Reduction: Interstage cooling brings compression closer to the ideal isothermal curve, dramatically lowering specific power (kW per m³/min).

  • 100,000-Hour Bearing Design Life: Because each stage only carries half the total pressure differential, radial and axial bearing loads are reduced by 50%. This doubles the mechanical lifespan of SKF bearings compared to single-stage airends.

  • Lower Operating Temperature: Air-cooled GAT units maintain a discharge temperature of ambient +15°C, while water-cooled models keep discharge air below 40°C, easing the thermal load on downstream dryers.

  • Tight Pressure Stability: Precision 5:6 rotor profiles and PID logic maintain target pressure within ±0.01 MPa.

CHAPTER 2: GAT SERIES FULL SPECIFICATION TABLES (17 MODELS)

The ZIQI GAT series encompasses 17 verified models categorized across three performance tiers. To review detailed canopy dimensions and mechanical drawings, visit our official GAT Series product page.

1. Compact Two-Stage Series (22 kW to 75 kW — Air-Cooled)

Air-cooled compact GAT models serve small-to-medium factories seeking two-stage energy efficiency on standard 380V/415V plant power.

ModelMotor PowerFAD @ 0.6 MPaFAD @ 0.7 MPaFAD @ 0.8 MPaFAD @ 1.0 MPaFAD @ 1.3 MPaNoise LevelDimensions (mm)WeightOutlet
GAT-22A22 kW / 30 HP4.20 m³/min3.95 m³/min3.50 m³/min3.20 m³/min2.60 m³/min64 ± 2 dB(A)1535 × 950 × 1500810 kgDN25
GAT-30A30 kW / 40 HP6.20 m³/min6.03 m³/min5.40 m³/min4.50 m³/min3.20 m³/min65 ± 2 dB(A)1750 × 1100 × 17001085 kgDN40
GAT-37A37 kW / 50 HP7.90 m³/min7.50 m³/min7.00 m³/min5.60 m³/min5.40 m³/min65 ± 2 dB(A)1750 × 1100 × 17001150 kgDN40
GAT-45A45 kW / 60 HP9.20 m³/min9.10 m³/min8.40 m³/min7.40 m³/min6.60 m³/min68 ± 2 dB(A)1750 × 1100 × 17001250 kgDN40
GAT-55A55 kW / 75 HP12.20 m³/min11.90 m³/min11.80 m³/min9.30 m³/min8.00 m³/min72 ± 2 dB(A)2350 × 1450 × 19502300 kgDN50
GAT-75A75 kW / 100 HP16.00 m³/min15.02 m³/min14.75 m³/min13.00 m³/min10.90 m³/min72 ± 2 dB(A)2350 × 1450 × 19502650 kgDN50

2. Industrial Two-Stage Series (90 kW to 185 kW)

Industrial GAT models provide high-volume air delivery for automotive, textile, and chemical plants.

ModelMotor PowerCoolingFAD @ 0.6 MPaFAD @ 0.7 MPaFAD @ 0.8 MPaFAD @ 1.0 MPaFAD @ 1.3 MPaNoise LevelDimensions (mm)WeightOutlet
GAT-90A90 kW / 120 HPAir-Cooled19.00 m³/min18.00 m³/min17.50 m³/min15.80 m³/min13.00 m³/min75 ± 2 dB(A)3000 × 1750 × 19203600 kgDN65
GAT-110A110 kW / 150 HPAir-Cooled24.00 m³/min23.00 m³/min20.40 m³/min18.00 m³/min16.00 m³/min76 ± 2 dB(A)3000 × 1750 × 19203980 kgDN65
GAT-132A132 kW / 180 HPAir-Cooled26.50 m³/min26.00 m³/min23.00 m³/min22.00 m³/min18.00 m³/min77 ± 2 dB(A)3000 × 1750 × 19204200 kgDN65
GAT-160W160 kW / 215 HPWater-Cooled32.50 m³/min32.07 m³/min28.00 m³/min26.00 m³/min22.50 m³/min77 ± 2 dB(A)3100 × 1800 × 22004700 kgDN80
GAT-185A/W185 kW / 250 HPAir / Water41.00 m³/min37.92 m³/min32.50 m³/min31.00 m³/min26.00 m³/min77 ± 2 dB(A)3100 × 1800 × 22005000 kgDN80

3. Heavy-Duty Two-Stage Series (200 kW to 355 kW)

Heavy-duty GAT models handle colossal continuous air flows up to 73.00 m³/min for primary manufacturing infrastructure.

ModelMotor PowerCoolingFAD @ 0.6 MPaFAD @ 0.7 MPaFAD @ 0.8 MPaFAD @ 1.0 MPaFAD @ 1.3 MPaNoise LevelDimensions (mm)WeightOutlet
GAT-200A/W200 kW / 270 HPAir / Water43.80 m³/min40.50 m³/min37.00 m³/min32.50 m³/min30.50 m³/min80 ± 2 dB(A)3850 × 2250 × 20605500 kgDN100
GAT-220A/W220 kW / 300 HPAir / Water49.50 m³/min49.00 m³/min41.00 m³/min36.50 m³/min32.00 m³/min80 ± 2 dB(A)3850 × 2250 × 20606200 kgDN100
GAT-250A/W250 kW / 340 HPAir / Water56.00 m³/min54.00 m³/min49.00 m³/min40.50 m³/min36.00 m³/min80 ± 2 dB(A)3850 × 2250 × 20606300 kgDN100
GAT-280W280 kW / 380 HPWater-Cooled61.00 m³/min60.00 m³/min54.00 m³/min46.00 m³/min41.00 m³/min82 ± 2 dB(A)4650 × 2300 × 24007300 kgDN125
GAT-315W315 kW / 425 HPWater-Cooled70.00 m³/min—60.00 m³/min50.00 m³/min45.00 m³/min84 ± 2 dB(A)4650 × 2300 × 24009000 kgDN125
GAT-355W355 kW / 480 HPWater-Cooled73.00 m³/min—70.00 m³/min60.00 m³/min49.00 m³/min86 ± 2 dB(A)4650 × 2300 × 240010000 kgDN125

CHAPTER 3: CHOOSING BETWEEN 5 PRESSURE OPTIONS

Matching compressor working pressure precisely to plant requirements avoids wasting power. For every 1 bar (0.1 MPa) increase in discharge pressure above actual process needs, electrical energy consumption increases by roughly 7%.

  • 0.6 MPa (6 bar): Ideal for low-pressure applications like pneumatic conveying, glass blowing, and wastewater aeration basins.

  • 0.7 MPa (7 bar) & 0.8 MPa (8 bar): The standard pressure benchmark for general industrial shop air, automated packaging lines, and textile looms.

  • 1.0 MPa (10 bar): Required for laser cutting tools, heavy metal stamping, or distribution networks with long piping runs.

  • 1.3 MPa (13 bar): Specialized high-pressure process air, PET preform molding, and deep rock drilling.

⚠️ Pressure Limitation Note on Heavy-Duty Models        Engineering buyers should note that GAT-315W (315 kW) and GAT-355W (355 kW) do not offer a 0.7 MPa (7 bar) rating. Due to internal volumetric air velocity constraints across massive two-stage rotor profiles, these models are engineered specifically for 0.6, 0.8, 1.0, and 1.3 MPa applications.

CHAPTER 4: AIR-COOLED VS WATER-COOLED SELECTION

Heat rejection infrastructure dictates compressor cooling selection:

  • 22 kW to 132 kW (Air-Cooled Standard): Models GAT-22A through GAT-132A feature heavy-duty aluminum coolers and axial fans, eliminating external water plumbing.

  • 160 kW, 185 kW, 200 kW, 220 kW, 250 kW (Dual Option): These mid-to-large models offer air-cooled (A) or water-cooled (W) configurations. Choose water-cooling if the compressor room lacks adequate ventilation or ambient temperatures exceed 45°C.

  • 280 kW to 355 kW (Water-Cooled Only): Large-capacity GAT-280W, GAT-315W, and GAT-355W models require connection to facility cooling water circuits (shell-and-tube heat exchangers) to manage massive heat rejection loads efficiently.

CHAPTER 5: GAT FIXED SPEED VS GAT-VFC (VSD)

All 17 GAT models are available in both fixed-speed and Variable Speed Drive (VSD) configurations (indicated by the suffix VFC or CFV).

For steady 24/7 baseload production, fixed-speed GAT units deliver maximum mechanical efficiency. For facilities with fluctuating air consumption across shifts, GAT-VFC models utilize heavy-duty vector inverters to adjust motor speed dynamically down to 10% of rated output without cycling into unloader mode.

For detailed variable speed energy calculations, consult our VSD sizing and ROI guide or review our standard GAS fixed speed series. Real-world validation of two-stage VSD energy efficiency is demonstrated in our GAT-55ACF retrofit case study.

CHAPTER 6: 5-STEP GAT SELECTION PROTOCOL

Execute this 5-step engineering protocol when specifying a GAT two-stage compressor for plant modernization or greenfield expansion:

ZIQI GAT Sizing & Selection Protocol

1
Identify Minimum System Operating Pressure: Determine the exact pressure required at the point of use (0.6, 0.7, 0.8, 1.0, or 1.3 MPa). Do not over-specify pressure.
2
Calculate Total Concurrent Volumetric Flow: Sum the maximum FAD demand (m³/min) of all operating equipment. Add a 15% expansion safety margin. Cross-reference against Chapter 2 specification tables.
3
Determine Cooling Infrastructure: For capacities ≤132 kW, choose air-cooled (A). For ≥185 kW in hot or enclosed utility rooms, specify water-cooled (W).
4
Select Drive Architecture (Fixed Speed vs VFC): If load variation exceeds 20%, specify a GAT-VFC unit to eliminate unloader energy losses.
5
Verify Motor Efficiency Rating: Ensure the compressor integrates premium motor technology. All GAT units feature WEG IE4 motor efficiency with IP55 protection as standard.

Explore Related Product Lines & Technical Resources

Frequently Asked Questions

What power range does the GAT two-stage series cover?
The ZIQI GAT Series spans 17 distinct models from 22 kW (30 HP) up to 355 kW (480 HP), delivering volumetric flow rates from 4.20 m³/min to 73.00 m³/min across 5 standard pressure levels.
How much energy does a two-stage compressor save vs single-stage?
By dividing total compression into two distinct stages with intermediate intercooling, GAT two-stage compressors reduce internal thermodynamic compression work, achieving up to 15% electrical power savings compared to single-stage machines.
What pressure options are available on the GAT series?
The GAT series offers 5 standard working pressure options: 0.6 MPa (6 bar), 0.7 MPa (7 bar), 0.8 MPa (8 bar), 1.0 MPa (10 bar), and 1.3 MPa (13 bar).
Which GAT models are water-cooled?
Models from 22 kW to 132 kW are air-cooled (A). GAT-160W is water-cooled. Models from 185 kW to 250 kW offer both air-cooled and water-cooled variants (A/W). Heavy-duty models from 280 kW to 355 kW are water-cooled only (W).
What does the VFC suffix mean on a GAT model?
The VFC or CFV suffix indicates an integrated Variable Frequency Control (VSD) system with vector control inverters, allowing the compressor to modulate speed down to 10% of rated capacity to track fluctuating air demand.
Why does two-stage compression extend airend life?
Because each stage only handles a fraction of the overall pressure ratio (roughly 2.5:1 per stage), the differential pressure across the rotors is drastically lower. This reduces radial and axial bearing loads by 50%, enabling a 100,000-hour design life.
What is the discharge temperature of a two-stage compressor?
Interstage cooling keeps internal air temperatures significantly lower than single-stage units. Air-cooled GAT models maintain a discharge temperature of ambient +15°C, while water-cooled models discharge compressed air at <40°C.
Can I get a GAT compressor at 0.7 MPa in all model sizes?
The 0.7 MPa (7 bar) option is available across 15 models from 22 kW up to 280 kW. However, the heavy-duty GAT-315W (315 kW) and GAT-355W (355 kW) models are not offered in 0.7 MPa due to high volumetric flow velocity constraints.

Request a Two-Stage GAT Technical Proposal

Upgrading your factory's compressed air station or evaluating two-stage energy savings? Contact ZIQI's engineering team for custom flow calculations, CAD layout drawings, and direct factory pricing.

Basic Information
  • Year Established
    --
  • Business Type
    --
  • Country / Region
    --
  • Main Industry
    --
  • Main Products
    --
  • Enterprise Legal Person
    --
  • Total Employees
    --
  • Annual Output Value
    --
  • Export Market
    --
  • Cooperated Customers
    --
Chat
Now

Send your inquiry

Choose a different language
╳
العربية
Беларуская
Deutsch
Ελληνικά
English
Español
français
Magyar
italiano
Nederlands
Português
русский
Current language:English