ZIQI Compressor For Global Energy Saving, Welcome To Contact Us.
008615026767628

Compressed Air Systems Engineer
ZIQI Compressor Group · Updated July 2026
In continuous 24/7 heavy industrial facilities, electricity accounts for up to 80% of an air compressor's total lifecycle cost. When air demand is large or discharge pressure exceeds 8 bar, single-stage rotary screw compressors experience exponential heat and thermodynamic friction losses. As an established global air compressor manufacturer, ZIQI Compressor Group engineered the GAT Two-Stage Rotary Screw Series to divide compression into two intercooled stages, achieving near-isothermal compression efficiency. Sizing a two-stage machine requires matching total plant Free Air Delivery (FAD) across 5 standard pressure ratings (0.6, 0.7, 0.8, 1.0, and 1.3 MPa) while navigating cooling configurations (air-cooled vs. water-cooled) and optional Variable Frequency Control (VFC). This engineering guide details ZIQI's 17 verified GAT models spanning 22 kW to 355 kW.
Sizing a GAT two-stage screw compressor requires evaluating required operating pressure (0.6, 0.7, 0.8, 1.0, or 1.3 MPa), total volumetric flow (4.20 to 73.00 m³/min), and plant heat rejection infrastructure. For medium baseloads from 22 kW to 132 kW, air-cooled models (GAT-22A to GAT-132A) offer turnkey installation. For heavy baseloads from 185 kW to 355 kW, water-cooled variants manage intensive heat loads. All GAT models feature 5:6 asymmetric rotor profiles, WEG IE4 IP55 motors, 1:1 direct flexible couplings, and interstage oil-injection cooling, cutting power consumption by up to 15% compared to single-stage units.
Compressing atmospheric air to high pressure in a single rotor chamber generates intense heat. Per gas thermodynamic law ($PV^n = C$), higher compression ratios elevate air temperature, increasing internal air resistance and power demand.
ZIQI GAT two-stage compressors utilize twin tandem rotor sets housed within a heavy-duty cast iron body. Atmospheric air enters the primary low-pressure stage, where it is compressed to an intermediate pressure ratio (approx. 2.5:1). The air then passes through an integrated interstage fluid spray chamber, which absorbs thermal energy and drops the temperature significantly before the air enters the secondary high-pressure stage. To compare thermodynamic efficiency factors between designs, see our two-stage vs single-stage comparison.
Up to 15% Power Reduction: Interstage cooling brings compression closer to the ideal isothermal curve, dramatically lowering specific power (kW per m³/min).
100,000-Hour Bearing Design Life: Because each stage only carries half the total pressure differential, radial and axial bearing loads are reduced by 50%. This doubles the mechanical lifespan of SKF bearings compared to single-stage airends.
Lower Operating Temperature: Air-cooled GAT units maintain a discharge temperature of ambient +15°C, while water-cooled models keep discharge air below 40°C, easing the thermal load on downstream dryers.
Tight Pressure Stability: Precision 5:6 rotor profiles and PID logic maintain target pressure within ±0.01 MPa.
The ZIQI GAT series encompasses 17 verified models categorized across three performance tiers. To review detailed canopy dimensions and mechanical drawings, visit our official GAT Series product page.
Air-cooled compact GAT models serve small-to-medium factories seeking two-stage energy efficiency on standard 380V/415V plant power.
| Model | Motor Power | FAD @ 0.6 MPa | FAD @ 0.7 MPa | FAD @ 0.8 MPa | FAD @ 1.0 MPa | FAD @ 1.3 MPa | Noise Level | Dimensions (mm) | Weight | Outlet |
|---|---|---|---|---|---|---|---|---|---|---|
| GAT-22A | 22 kW / 30 HP | 4.20 m³/min | 3.95 m³/min | 3.50 m³/min | 3.20 m³/min | 2.60 m³/min | 64 ± 2 dB(A) | 1535 × 950 × 1500 | 810 kg | DN25 |
| GAT-30A | 30 kW / 40 HP | 6.20 m³/min | 6.03 m³/min | 5.40 m³/min | 4.50 m³/min | 3.20 m³/min | 65 ± 2 dB(A) | 1750 × 1100 × 1700 | 1085 kg | DN40 |
| GAT-37A | 37 kW / 50 HP | 7.90 m³/min | 7.50 m³/min | 7.00 m³/min | 5.60 m³/min | 5.40 m³/min | 65 ± 2 dB(A) | 1750 × 1100 × 1700 | 1150 kg | DN40 |
| GAT-45A | 45 kW / 60 HP | 9.20 m³/min | 9.10 m³/min | 8.40 m³/min | 7.40 m³/min | 6.60 m³/min | 68 ± 2 dB(A) | 1750 × 1100 × 1700 | 1250 kg | DN40 |
| GAT-55A | 55 kW / 75 HP | 12.20 m³/min | 11.90 m³/min | 11.80 m³/min | 9.30 m³/min | 8.00 m³/min | 72 ± 2 dB(A) | 2350 × 1450 × 1950 | 2300 kg | DN50 |
| GAT-75A | 75 kW / 100 HP | 16.00 m³/min | 15.02 m³/min | 14.75 m³/min | 13.00 m³/min | 10.90 m³/min | 72 ± 2 dB(A) | 2350 × 1450 × 1950 | 2650 kg | DN50 |
Industrial GAT models provide high-volume air delivery for automotive, textile, and chemical plants.
| Model | Motor Power | Cooling | FAD @ 0.6 MPa | FAD @ 0.7 MPa | FAD @ 0.8 MPa | FAD @ 1.0 MPa | FAD @ 1.3 MPa | Noise Level | Dimensions (mm) | Weight | Outlet |
|---|---|---|---|---|---|---|---|---|---|---|---|
| GAT-90A | 90 kW / 120 HP | Air-Cooled | 19.00 m³/min | 18.00 m³/min | 17.50 m³/min | 15.80 m³/min | 13.00 m³/min | 75 ± 2 dB(A) | 3000 × 1750 × 1920 | 3600 kg | DN65 |
| GAT-110A | 110 kW / 150 HP | Air-Cooled | 24.00 m³/min | 23.00 m³/min | 20.40 m³/min | 18.00 m³/min | 16.00 m³/min | 76 ± 2 dB(A) | 3000 × 1750 × 1920 | 3980 kg | DN65 |
| GAT-132A | 132 kW / 180 HP | Air-Cooled | 26.50 m³/min | 26.00 m³/min | 23.00 m³/min | 22.00 m³/min | 18.00 m³/min | 77 ± 2 dB(A) | 3000 × 1750 × 1920 | 4200 kg | DN65 |
| GAT-160W | 160 kW / 215 HP | Water-Cooled | 32.50 m³/min | 32.07 m³/min | 28.00 m³/min | 26.00 m³/min | 22.50 m³/min | 77 ± 2 dB(A) | 3100 × 1800 × 2200 | 4700 kg | DN80 |
| GAT-185A/W | 185 kW / 250 HP | Air / Water | 41.00 m³/min | 37.92 m³/min | 32.50 m³/min | 31.00 m³/min | 26.00 m³/min | 77 ± 2 dB(A) | 3100 × 1800 × 2200 | 5000 kg | DN80 |
Heavy-duty GAT models handle colossal continuous air flows up to 73.00 m³/min for primary manufacturing infrastructure.
| Model | Motor Power | Cooling | FAD @ 0.6 MPa | FAD @ 0.7 MPa | FAD @ 0.8 MPa | FAD @ 1.0 MPa | FAD @ 1.3 MPa | Noise Level | Dimensions (mm) | Weight | Outlet |
|---|---|---|---|---|---|---|---|---|---|---|---|
| GAT-200A/W | 200 kW / 270 HP | Air / Water | 43.80 m³/min | 40.50 m³/min | 37.00 m³/min | 32.50 m³/min | 30.50 m³/min | 80 ± 2 dB(A) | 3850 × 2250 × 2060 | 5500 kg | DN100 |
| GAT-220A/W | 220 kW / 300 HP | Air / Water | 49.50 m³/min | 49.00 m³/min | 41.00 m³/min | 36.50 m³/min | 32.00 m³/min | 80 ± 2 dB(A) | 3850 × 2250 × 2060 | 6200 kg | DN100 |
| GAT-250A/W | 250 kW / 340 HP | Air / Water | 56.00 m³/min | 54.00 m³/min | 49.00 m³/min | 40.50 m³/min | 36.00 m³/min | 80 ± 2 dB(A) | 3850 × 2250 × 2060 | 6300 kg | DN100 |
| GAT-280W | 280 kW / 380 HP | Water-Cooled | 61.00 m³/min | 60.00 m³/min | 54.00 m³/min | 46.00 m³/min | 41.00 m³/min | 82 ± 2 dB(A) | 4650 × 2300 × 2400 | 7300 kg | DN125 |
| GAT-315W | 315 kW / 425 HP | Water-Cooled | 70.00 m³/min | — | 60.00 m³/min | 50.00 m³/min | 45.00 m³/min | 84 ± 2 dB(A) | 4650 × 2300 × 2400 | 9000 kg | DN125 |
| GAT-355W | 355 kW / 480 HP | Water-Cooled | 73.00 m³/min | — | 70.00 m³/min | 60.00 m³/min | 49.00 m³/min | 86 ± 2 dB(A) | 4650 × 2300 × 2400 | 10000 kg | DN125 |
Matching compressor working pressure precisely to plant requirements avoids wasting power. For every 1 bar (0.1 MPa) increase in discharge pressure above actual process needs, electrical energy consumption increases by roughly 7%.
0.6 MPa (6 bar): Ideal for low-pressure applications like pneumatic conveying, glass blowing, and wastewater aeration basins.
0.7 MPa (7 bar) & 0.8 MPa (8 bar): The standard pressure benchmark for general industrial shop air, automated packaging lines, and textile looms.
1.0 MPa (10 bar): Required for laser cutting tools, heavy metal stamping, or distribution networks with long piping runs.
1.3 MPa (13 bar): Specialized high-pressure process air, PET preform molding, and deep rock drilling.
Heat rejection infrastructure dictates compressor cooling selection:
22 kW to 132 kW (Air-Cooled Standard): Models GAT-22A through GAT-132A feature heavy-duty aluminum coolers and axial fans, eliminating external water plumbing.
160 kW, 185 kW, 200 kW, 220 kW, 250 kW (Dual Option): These mid-to-large models offer air-cooled (A) or water-cooled (W) configurations. Choose water-cooling if the compressor room lacks adequate ventilation or ambient temperatures exceed 45°C.
280 kW to 355 kW (Water-Cooled Only): Large-capacity GAT-280W, GAT-315W, and GAT-355W models require connection to facility cooling water circuits (shell-and-tube heat exchangers) to manage massive heat rejection loads efficiently.
All 17 GAT models are available in both fixed-speed and Variable Speed Drive (VSD) configurations (indicated by the suffix VFC or CFV).
For steady 24/7 baseload production, fixed-speed GAT units deliver maximum mechanical efficiency. For facilities with fluctuating air consumption across shifts, GAT-VFC models utilize heavy-duty vector inverters to adjust motor speed dynamically down to 10% of rated output without cycling into unloader mode.
For detailed variable speed energy calculations, consult our VSD sizing and ROI guide or review our standard GAS fixed speed series. Real-world validation of two-stage VSD energy efficiency is demonstrated in our GAT-55ACF retrofit case study.
Execute this 5-step engineering protocol when specifying a GAT two-stage compressor for plant modernization or greenfield expansion:
Upgrading your factory's compressed air station or evaluating two-stage energy savings? Contact ZIQI's engineering team for custom flow calculations, CAD layout drawings, and direct factory pricing.
Copyright © 2026 ZIQI Compressor (Shanghai) Co., Ltd - All rights reserved.