ZIQI Compressor For Global Energy Saving, Welcome To Contact Us.
008615026767628
Updated October 2026
ISO 8573-1 Air Quality Classes Explained: What Class 0 Really Means for Compressed Air
Authored by ZIQI's field engineering team; ZIQI products mentioned are manufactured by the publisher.
A purity class on a quotation is only meaningful if it says which contaminant it refers to. This guide explains how ISO 8573-1:2010 grades compressed air, gives you the full oil class table from Class 0 to Class 4, and shows why filtration cannot lift an oil-flooded machine into Class 0.
Oil content figures are the ISO 8573-1:2010 class thresholds (measured as total oil in mg/m³). Class assignments in a purchase contract are agreed between buyer and supplier; verify the exact class and test method on the datasheet.
Sources: ZIQI "Oil-Free vs Oil-Flooded Compressor" comparison, ZIQI "Oil-Free Air Compressor Buyer's Guide 2026" and ZIQI "Water-Lubricated vs Dry Oil-Free Compressor", all published on ziqi-group.net. The energy penalty assumes a 75 kW oil-flooded machine at 6,000 annual hours, $0.12 per kWh and a 0.7 bar filtration pressure drop.
ISO 8573-1:2010 grades compressed air on three independent scales — solid particulates, water and total oil — so a single "class" number on a quotation is never a complete specification. On the oil scale, Class 0 is 0.000 mg/m³ (undetectable) and Class 1 is ≤ 0.01 mg/m³. ZIQI's published position is that Class 0 is a custom design standard written between manufacturer and buyer, strictly more stringent than Class 1, and that filtration cannot lift an oil-flooded machine to Class 0. Specify all three scales separately in your purchase order, and demand third-party certification.
If you are comparing quotations from an air compressor manufacturer and one of them promises "Class 0 air" over the phone, the first question is not about price — it is about which of the three contaminant families that number refers to. Compressed air purity is not one measurement. It is three, and they behave independently. This guide walks through how ISO 8573-1 works, the oil class table in full, and the two engineering claims that decide whether a machine can legitimately be called Class 0.
"Oil-free" is not a marketing adjective; it is an internationally regulated term governed by the International Organization for Standardization. When engineers discuss oil carryover, they reference ISO 8573-1:2010, which classifies compressed air based on the concentration of three contaminant families:
Solid particulates — rust, scale, dust and pipe debris carried through the distribution system.
Water — present as vapour and, below the pressure dew point, as liquid condensate.
Total oil — and this is the part buyers most often misread: total oil means aerosol, liquid and vapour combined, not just visible mist.
Each family is graded on its own numbered scale, and a machine can legitimately hold different class numbers for each. A compressor that delivers Class 0 oil can still deliver wet, particle-laden air if the dryer and filtration downstream are undersized — which is why the purity specification you send to suppliers has to name all three.
The oil scale is the one that drives capital cost, and it is the one most often quoted. ZIQI publishes the following table in its oil-free versus oil-flooded comparison:
| ISO Class | Max total oil content | Typical industrial application |
|---|---|---|
| Class 0 | 0.000 mg/m³ (undetectable) | Pharma, food, semiconductor |
| Class 1 | ≤ 0.01 mg/m³ | Electronics assembly |
| Class 2 | ≤ 0.1 mg/m³ | General manufacturing |
| Class 3 | ≤ 1.0 mg/m³ | Pneumatic tools |
| Class 4 | ≤ 5.0 mg/m³ | Construction equipment |
| Source | ISO 8573-1:2010, purity classes by total oil content (mg/m³). Class assignments in a purchase contract are agreed between buyer and supplier. | |
Two details in that table are routinely missed. First, Class 0 does not mean zero contaminants exist in the ambient air drawn into the compressor; it means the compressor itself adds absolutely zero total oil. If your intake sits next to a diesel bay, the machine will pull in whatever is in the air and pass it through. Second, Class 0 is not a measured value on this table the way Class 1 to Class 4 are.
That distinction matters commercially. A supplier who quotes "Class 0" without a certificate, a coating specification and a test protocol is quoting an aspiration. Full comparison data is published in our oil-free versus oil-flooded compressor comparison.
Because the three families are graded separately, purity is always a three-part specification. ZIQI's cleanroom sizing guidance gives the clearest example: compressed air in direct contact with active pharmaceutical ingredients, used for vial blow-off and fluid bed dryers, requires ISO 8573-1 Class 0 air combined with a −40 °C desiccant pressure dew point to eliminate microbial proliferation risk.
Read that carefully — the Class 0 number covers oil only. The −40 °C figure is a separate water requirement, delivered by a desiccant dryer, and it does not appear anywhere in the oil class table. Semiconductor fabs add a third axis: photolithography tools and wafer handling robotics need Class 0 air to prevent volatile organic compounds and trace hydrocarbons from reaching the process, on top of the cleanroom's own ISO 5 or ISO 6 particulate envelope.
For most general manufacturing, the water and particulate requirements are the binding constraint rather than the oil class. Air at Class 2 or Class 3 oil will run a fabrication shop indefinitely; air that condenses in the piping will not. Budget the dryer and the filtration train as separate line items, and specify them separately.
This is the most expensive misconception in compressed air procurement, and it deserves a direct answer: no. ZIQI's engineering comparison describes the belief that a cheaper oil-flooded compressor plus a large filter bank can reach Class 0 as structurally false.
Here is the mechanism. In an oil-flooded screw, oil is injected into the compression chamber for sealing and cooling, so the discharge air is heavily laden with it. A premium mechanical separator reduces carryover to roughly 2 to 3 parts per million. Adding downstream coalescing filters gets you to 0.01 mg/m³, which is ISO Class 1 — never mathematically zero.
The harder limit is temperature. A coalescing filter traps liquid aerosol; an activated carbon tower adsorbs oil vapour. But activated carbon only traps vapour when ambient temperature is relatively low, typically under 30 °C. If the compressor room heats up in summer, oil vapour passes straight through the carbon bed unchecked — which is exactly when plants run hardest.
Even if filtration worked, it would not be free. Cleaning oil-flooded air to near-Class 0 requires a heavy train: a 1-micron general purpose filter, a 0.01-micron high-efficiency coalescing filter and a large activated carbon tower. ZIQI's published example calculates the penalty for a 75 kW oil-flooded compressor at 6,000 annual hours and $0.12 per kWh, assuming a conservative 0.7 bar pressure drop:
75 kW × 7% efficiency loss per bar × 0.7 bar = 3.7 kW of additional power demand.
3.7 kW × 6,000 hours × $0.12 per kWh = $2,664 per year simply to push air through the filters.
Over ten years that is $26,640 of energy with no compressed air produced by it.
Add that penalty to the base case and the 10-year total cost of the oil-flooded route rises from $43,000 to $69,640, against $34,000 for an oil-free machine. The oil-free TCO advantage widens from roughly $9,000 to $35,640 over the decade. Filtration does not close the gap — it widens it. The full arithmetic is in our air compressor total cost of ownership guide.
If filtration cannot reach Class 0, the class has to be built into the machine. In an oil-free screw, no fluid enters the compression chamber at all. ZIQI builds both of the dominant oil-free architectures, and they reach the same purity class by very different thermodynamic routes.
Water-lubricated single-stage (OFW series, 7.5–75 kW). Pure water is injected into the chamber, where it absorbs compression heat instantly and keeps the process below 50 °C — an isothermal rather than adiabatic cycle. Cooler air is denser and easier to compress, and ZIQI publishes roughly 15% higher efficiency against traditional dry screw designs. Sealing is by a renewable pure water film rather than a coating that wears off, and rotors are solid 304 or 316 stainless steel.
Dry two-stage (OFD series, 45–355 kW). Traditional dry screws run with no liquid cooling at all, so compression temperatures soar to 180 °C to 200 °C. Rotors never touch, relying on air gaps and a chemical coating — ZIQI uses an Ultracoat PTFE plus MoS₂ polymer coating on coated carbon steel or stainless secondary rotors — with a published maintenance lifecycle of 40,000 to 60,000 operating hours before the first coating overhaul.
Both routes deliver 0.000 mg/m³, ISO Class 0 purity. The choice between them is a duty-cycle and maintenance decision, not a purity decision. Our water-lubricated versus dry oil-free comparison breaks down the trade-off, and the oil-free air compressor buyer's guide covers sizing by industry.
The class you actually need is dictated by what the air touches, not by how conservative your quality department is. ZIQI's published industry guidance maps roughly as follows:
Pharmaceutical cGMP manufacturing (FDA 21 CFR Part 211, EU GMP Annex 1) — Class 0 air plus −40 °C desiccant pressure dew point for anything in direct contact with active pharmaceutical ingredients, vial blow-off or fluid bed dryers.
Food and beverage — Class 0 for PET blowing, packaging and fermentation lines where air contacts the product directly; 3-A Sanitary Standards documentation typically required.
Semiconductor and microelectronics (ISO 5 / ISO 6 cleanrooms) — Class 0 to keep volatile organic compounds and trace hydrocarbons off photolithography tools and wafer handling robotics.
Automotive paint and coating — hydrocarbon vapour causes paint to separate from primer, producing surface adhesion failures known as fisheyes or craters.
General fabrication and pneumatic conveying — Class 2 to Class 3 is normally sufficient, and specifying Class 0 here is capital spent without a return.
The asymmetric risk is what makes this a procurement decision rather than an engineering one. ZIQI's comparison page puts it in one line: the cost of one contaminated pharmaceutical batch typically exceeds the price premium of an oil-free compressor by 10 to 50 times. You are not buying a purity class; you are buying the elimination of a tail risk that does not scale with machine size.
If your facility mandates ISO Class 0 air, interrogate the supply chain rather than reading brochures. ZIQI publishes the following pre-purchase checklist, and any serious manufacturer should answer all six in writing:
Beyond purity, confirm the compliance package your market requires. Exports to the European Union need CE Machinery Directive (2006/42/EC) and Pressure Equipment Directive (PED 2014/68/EU) certification; North American projects require ASME Section VIII Division 1 U-stamped pressure vessels and UL 508A control panels. Our air compressor HS code guide covers the landed-cost side of the same decision.
ZIQI publishes a standard 2-year major component warranty with lifetime technical support on export oil-free units, an MOQ of 1 unit on standard industrial models, and production and testing lead times of 10 to 20 business days depending on custom voltage and inverter specification. Itemised export quotations (FOB, CIF or DDP) are issued after technical review.
Send us your industry, pressure dew point requirement and peak flow in m³/min. Our engineers will return the correct ISO 8573-1 specification for all three contaminant families, plus an itemised export quotation. Or email sales@ziqi-group.com directly.
Copyright © 2026 ZIQI Compressor (Shanghai) Co., Ltd - All rights reserved.