ENERGY SAVING CASES
VR

Shanghai XX Auto Energy-saving Upgrade Project

Case Study: Saving 82,000 kWh/Year for Shanghai Automotive Motor Plant
Success Story

Project: Shanghai Automotive Motor Co., Ltd. Energy Retrofit

Replacing 2 inefficient units with 1 ZIQI Two-Stage VSD unit to slash energy costs by 40%.

Location            Shanghai, China
Industry            Automotive Parts
Solution            ZIQI GAT-55A (Two-Stage)
Result            82,000 kWh Saved/Year

1. The Challenge: Why was the old system wasting money?

Shanghai XX Automobile Motor Co., Ltd. was operating a mixed system consisting of one 37kW Screw Compressor (Competitor Brand) and one 37kW Single-Stage Inverter Compressor.

⚠️ Engineer's Diagnosis

The problem wasn't just the age of the machines. The issue was "System Fighting". Two smaller compressors were constantly loading and unloading to match demand, leading to huge energy spikes. Plus, single-stage compression creates excessive heat, wasting electricity.

Old air compressor room before renovation
Before: Cluttered room with 2 inefficient units.
New ZIQI Two-Stage Compressor GAT-55A installed
After: Clean setup with 1 ZIQI Two-Stage Unit.

2. The Solution: Two-Stage VSD Consolidation

ZIQI engineers proposed replacing both units with a single 55kW Two-Stage VSD Compressor (GAT-55A CFV).

💡 Why Two-Stage?
       By compressing air in two steps and cooling it in between, we achieve near-isothermal compression. This physics principle alone reduces energy consumption by 15% compared to single-stage models.

3. Data Verification: The Numbers Don't Lie

We conducted a rigorous 12-hour meter reading test to compare the Specific Power (kW·h/Nm³)—the only metric that matters.

System StatusPower ConsumedAir ProducedSpecific Power (Lower is Better)
Before (Old Units)690.8 kW·h3,322 Nm³0.2075 kW·h/Nm³
After (ZIQI GAT-55A)390.0 kW·h3,139 Nm³0.1240 kW·h/Nm³
(-40% Reduction)

*Data sourced from on-site electric flow meters (Feb 26 vs Feb 28, 2024).

4. The ROI: Real Money Saved

The specific power dropped from 0.2075 to 0.1240 kW·h/Nm³. What does this mean for the bank account?

Annual Electricity Savings
81,792 kW·h
Calculation: (0.0835 kW·h saved) × (3,139 m³/day) × (312 days)

≈ ¥65,000 - ¥80,000 RMB Saved Per Year!

"The ZIQI unit is so quiet we sometimes check to see if it's running. But the electricity bill proves it's working better than ever."        — Plant Manager, Shanghai Automotive Motor Co.

Stop Burning Money on Old Compressors.

Let ZIQI engineers conduct a free energy audit for your factory.

Request Free Energy Audit »
Basic Information
  • Year Established
    --
  • Business Type
    --
  • Country / Region
    --
  • Main Industry
    --
  • Main Products
    --
  • Enterprise Legal Person
    --
  • Total Employees
    --
  • Annual Output Value
    --
  • Export Market
    --
  • Cooperated Customers
    --
Chat
Now

Send your inquiry

Choose a different language
╳
العربية
Беларуская
Deutsch
Ελληνικά
English
Español
français
Magyar
italiano
Nederlands
Português
русский
Current language:English