Compressed Air Systems Engineer
ZIQI Compressor Group · Updated July 2026
In cleanroom-dependent industries such as pharmaceutical synthesis, semiconductor wafer fabrication, and high-purity chemical processing, introducing even microscopic hydrocarbon aerosols can destroy entire production batches. As a global air compressor manufacturer, ZIQI Compressor Group engineers the OFD Dry Oil-Free Screw Compressor series to eliminate oil at the compression source. Sizing a dry screw machine requires matching facility Free Air Delivery (FAD) demands while navigating thermodynamic cooling limits, pressure variants (7, 8, and 10 bar), and rotor coating longevity. This technical guide provides exact specification tables and a 4-step engineering protocol for ZIQI's 14 verified OFD models ranging from 45 kW to 355 kW.
Sizing a dry oil-free screw air compressor requires evaluating power rating (45 kW to 355 kW), volumetric flow (6.4 m³/min to 58.5 m³/min), and heat rejection method. For medium-capacity applications between 45 kW and 185 kW (OFD-45A to OFD-185A), air-cooled models eliminate external water piping. For heavy industrial plant baseloads between 200 kW and 355 kW (OFD-200W to OFD-355W), water-cooled models are mandatory to manage high two-stage compression heat ratios. All OFD models feature ISO 8573-1 Class 0 oil-free air, Ultracoat PTFE + MoS₂ rotor protection, and stainless steel second-stage rotors to prevent moisture oxidation.
The ZIQI OFD series spans 14 verified industrial models. Sizing begins by matching facility flow demands against exact factory acceptance test (FAT) Free Air Delivery numbers at 0.7 MPa (7 bar), 0.8 MPa (8 bar), or 1.0 MPa (10 bar).
Air-cooled OFD-A models integrate heavy-duty aluminum plate-fin coolers and axial fans. They are optimal for facilities without dedicated cooling water loops.
| Model | Motor Power | FAD @ 0.7 MPa (7 bar) | FAD @ 0.8 MPa (8 bar) | FAD @ 1.0 MPa (10 bar) | Noise Level |
|---|---|---|---|---|---|
| OFD-45A | 45 kW / 60 HP | 7.6 m³/min | 6.6 m³/min | 6.4 m³/min | 80 ± 3 dB(A) |
| OFD-55A | 55 kW / 73 HP | 9.2 m³/min | 9.1 m³/min | 8.0 m³/min | 80 ± 3 dB(A) |
| OFD-75A | 75 kW / 100 HP | 12.6 m³/min | 11.6 m³/min | 10.9 m³/min | 80 ± 3 dB(A) |
| OFD-90A | 90 kW / 120 HP | 13.4 m³/min | 13.3 m³/min | 12.5 m³/min | 80 ± 3 dB(A) |
| OFD-110A | 110 kW / 147 HP | 20.0 m³/min | 18.8 m³/min | 16.4 m³/min | 82 ± 3 dB(A) |
| OFD-132A | 132 kW / 177 HP | 23.6 m³/min | 22.2 m³/min | 19.9 m³/min | 82 ± 3 dB(A) |
| OFD-160A | 160 kW / 214 HP | 26.9 m³/min | 25.5 m³/min | 23.6 m³/min | 82 ± 3 dB(A) |
| OFD-185A | 185 kW / 248 HP | 29.8 m³/min | 29.7 m³/min | 26.8 m³/min | 82 ± 3 dB(A) |
Water-cooled OFD-W models connect directly to facility cooling towers. They deliver superior thermal equilibrium during continuous 24/7 full-load baseload operation.
| Model | Motor Power | FAD @ 0.7 MPa (7 bar) | FAD @ 0.8 MPa (8 bar) | FAD @ 1.0 MPa (10 bar) | Noise Level |
|---|---|---|---|---|---|
| OFD-200W | 200 kW / 268 HP | 33.5 m³/min | 33.4 m³/min | 29.9 m³/min | 85 ± 3 dB(A) |
| OFD-220W | 220 kW / 295 HP | 36.0 m³/min | 35.9 m³/min | 33.3 m³/min | 85 ± 3 dB(A) |
| OFD-250W | 250 kW / 335 HP | 42.9 m³/min | 42.7 m³/min | 38.3 m³/min | 85 ± 3 dB(A) |
| OFD-280W | 280 kW / 375 HP | 46.8 m³/min | 45.7 m³/min | 42.7 m³/min | 85 ± 3 dB(A) |
| OFD-315W | 315 kW / 422 HP | 51.5 m³/min | 51.3 m³/min | 46.8 m³/min | 90 ± 3 dB(A) |
| OFD-355W | 355 kW / 476 HP | 58.5 m³/min | 57.9 m³/min | 51.0 m³/min | 90 ± 3 dB(A) |
A frequent question from plant engineering teams is why dry oil-free screw air compressors transition from air-cooling to water-cooling above 185 kW. The reason lies in thermodynamics and rotor thermal expansion physics.
In an oil-flooded compressor, injected lubricant absorbs up to 80% of compression heat directly inside the rotor pocket. In a dry screw compressor, no liquid is present in the chamber. Air temperatures exiting the first stage frequently reach 160°C to 200°C before passing into the intercooler. For machines up to 185 kW (such as the OFD-185A), high-static axial cooling fans can reject this thermal energy into ambient air while keeping the canopy temperature within safe margins. To review complete model features and physical dimensions, visit our OFD dry oil-free screw compressor product page.
Above 200 kW, heat generation scales dramatically. Attempting to cool a 355 kW dry screw machine using ambient air would require massive cooling fans, creating excessive ducting requirements and elevated plant noise (90+ dB). Water-cooling utilizes shell-and-tube heat exchangers with shell-side water circulation, maintaining steady thermal equilibrium regardless of summer ambient spikes. Facilities with lower volumetric requirements (15 kW to 160 kW) can also evaluate our OFW water-lubricated oil-free series.
When specifying air purity for cleanroom validation, procurement teams must distinguish between ISO 8573-1 Class 1 and ISO 8573-1 Class 0.
Class 1 Particulate: 0.1–0.5 µm ≤ 20,000 particles/m³; 0.5–1.0 µm ≤ 400 particles/m³; 1.0–5.0 µm ≤ 10 particles/m³.
Class 1 Moisture: Pressure Dew Point (PDP) ≤ −40°C.
Class 1 Total Oil: Concentration of liquid oil, aerosol, and oil vapor strictly ≤ 0.01 mg/m³.
Because dry screw rotors do not touch and have no liquid barrier seal, efficiency depends on ultra-tight rotor clearances. Without protective surface treatment, high temperature and intake moisture cause bare metal rotors to erode, expanding clearances and dropping volumetric delivery.
ZIQI OFD compressors utilize Ultracoat, a proprietary composite coating combining Teflon (PTFE) and Molybdenum Disulfide (MoS₂). Ultracoat is molecularly bonded to the precision-machined rotor profiles. It withstands continuous operating temperatures up to 220°C without flaking or thermal degradation, preserving tight tolerances for 40,000 to 60,000 operating hours.
Furthermore, air exiting the first stage intercooler condenses atmospheric moisture. To eliminate rust oxidation in the high-pressure second stage, ZIQI constructs the second-stage rotors from solid high-grade stainless steel. Routine maintenance is limited to replacing intake air filter elements every 2,000 to 4,000 hours and inspecting timing gear lubrication.
Follow this 4-step engineering sequence when specifying an OFD dry screw compressor for new or replacement factory projects:
Planning a Class 0 cleanroom facility or upgrading an industrial compressed air station? Contact ZIQI's engineering team for custom flow calculations, CAD utility layouts, and direct factory pricing.