VR
  • Product Details
  • Product Applications
ISO 8573-1 Class 0 · 100% Oil-Free · Dry Compression

OFD Dry Oil-Free Screw Compressor

Ultracoat Teflon/MoS₂ Rotor Coating · Stainless Steel 2nd Stage · 14 Models from 45-355 kW · Air & Water-Cooled
Class 0
ISO 8573-1 Certified
100% Oil-Free
14
Models Available
45 - 355 kW
58.5
Max m³/min
@ 0.7 MPa
0
Oil Contamination
Zero Risk

Why ZIQI OFD Dry Oil-Free is the Safest Choice

When searching for a reliable pharmaceutical air compressor or food grade air compressor, ensuring absolute purity is critical. The ZIQI OFD Series is an advanced dry oil free compressor utilizing a dry compression chamber where no oil is injected. Combined with non-contact labyrinth seals, we guarantee it operates as a true ISO 8573-1 class 0 compressor — the highest standard in the industry.

As a leading oil free screw compressor, the OFD series handles applications ranging from small pharmaceutical cleanrooms to large-scale semiconductor fabs across 14 models (45 to 355 kW). Air-cooled models (45-185 kW) offer simple installation, while water-cooled models (200-355 kW) conquer high-capacity industrial demands. For water-lubricated oil-free technology with even lower noise, see our OFW series.

Core Technology

What Makes OFD Truly Oil-Free

Class 0 Certified
🍃

100% Dry Compression

No oil enters the compression chamber. Air is compressed by precisely machined rotors with tight clearances and non-contact labyrinth seals — guaranteeing zero oil contamination risk.

  • Safety: Ideal for food, pharma, and medical air

  • Purity: Eliminates oil filter and separator maintenance

  • Standard: Meets FDA/GMP/ISO requirements

Premium Coating
🛡️

Ultracoat Technology

Rotors and housing are coated with advanced Ultracoat (Teflon PTFE / Molybdenum Disulfide MoS₂) for dry lubrication, corrosion resistance, and tight sealing without oil.

  • Durability: Withstands high compression temperatures

  • Efficiency: Minimizes internal leakage between rotors

  • Longevity: Coating lasts for machine lifetime

⚙️

Stainless Steel 2nd Stage

High-pressure stage rotors are made of stainless steel to prevent rust in humid environments — ensuring air purity and extending air end lifespan even in tropical climates.

❄️

Dual Cooling Options

Air-cooled models (45-185 kW) for simple installation. Water-cooled models (200-355 kW) for high-capacity installations with lower discharge temperatures in hot environments.

🔇

Industrial Noise Control

Fully enclosed soundproof canopy with vibration-dampened mounts. Air-cooled models: 80-82 dB(A). Water-cooled models: 85-90 dB(A). Suitable for factory floor installation.

Application Scenarios

Where OFD Excels

💊

Pharmaceutical & Medical

GMP/FDA-compliant facilities requiring Class 0 oil-free air for tablet coating, capsule filling, API processing, and medical breathing air. Zero risk of oil contamination.

🍕

Food & Beverage

Direct-contact compressed air for food packaging, bottle blowing, dairy processing, and fermentation. Clean condensate can be directly discharged without oil-water treatment.

🔬

Electronics & Semiconductor

Ultra-clean air for wafer fabrication, PCB assembly, and cleanroom environments. Even microscopic oil particles cause defects in semiconductor processes.

🧪

Chemical & Textile

Chemical processing, textile dyeing, and surface treatment where oil contamination affects product quality. The OFD handles corrosive environments with stainless steel rotors.

Need Class 0 Oil-Free Air? Get a Custom Configuration for Your Application

Advantage

Oil-Injected vs. OFD Dry Oil-Free

FeatureOil-Injected CompressorZIQI OFD Dry Oil-Free
Air QualityContains Oil Vapor (Class 2-4)100% Oil-Free (Class 0)
Compression MethodOil injected for sealing & coolingDry rotors with Ultracoat coating
Oil SeparatorRequired (adds pressure drop)Not needed (zero oil in system)
Filtration CostHigh (oil filter + separator + coalescent)Low (air intake filter only)
CondensateOily water (needs treatment/disposal)Clean water (direct discharge)
Product ContaminationRisk of oil carryover to productZero risk — no oil in system
Regulatory ComplianceRequires additional downstream filtersInherently compliant (FDA/GMP/HACCP)
2nd Stage RotorsCarbon steel (standard)Stainless steel (anti-corrosion)
Rotor CoatingNone (oil provides lubrication)Ultracoat Teflon/MoS₂ (lifetime)
Selection Guide

How to Choose Your OFD Model

1

Confirm Oil-Free Requirement

Verify that your application requires ISO 8573-1 Class 0 oil-free air. Pharma, food, electronics, and medical typically mandate this. If Class 1-2 is acceptable, consider our OFW water-lubricated series.

2

Calculate Air Demand

The OFD offers 3 pressure options: 0.7, 0.8, and 1.0 MPa. Flow ranges from 6.4 m³/min (45 kW) to 58.5 m³/min (355 kW). Add 20% margin for peak demand and future expansion.

3

Choose Air or Water-Cooled

Air-cooled (OFD-45A to 185A) is simpler to install with no water circuit. Water-cooled (OFD-200W to 355W) is required above 185 kW and offers lower discharge temperatures in hot environments.

Full Specifications

OFD Series Parameters

14 models from 45 to 355 kW. All models are two-stage dry screw compression with Ultracoat rotors. Class 0 certified.

OFD Air-Cooled Series — 45 to 185 kW

Air-Cooled · Class 0
ModelMotorAir Delivery (m³/min) @ PressureNoise
dB(A)
Dimension L×W×H (mm)Weight (kg)Outlet
kWHP0.7 MPa0.8 MPa1.0 MPa
OFD-45A45607.66.66.480±32150×1550×18402400DN50
OFD-55A55739.29.18.080±32150×1550×18402600DN50
OFD-75A7510012.611.610.980±32350×1650×18402800DN50
OFD-90A9012013.413.312.580±32350×1650×18403400DN50
OFD-110A11014720.018.816.482±32850×1850×19103400DN65
OFD-132A13217723.622.219.982±32850×1850×19103450DN65
OFD-160A16021426.925.523.682±32850×1850×19103550DN65
OFD-185A18524829.829.726.882±32850×1850×19103950DN65

OFD Water-Cooled Series — 200 to 355 kW

Water-Cooled · Class 0
ModelMotorAir Delivery (m³/min) @ PressureNoise
dB(A)
Dimension L×W×H (mm)Weight (kg)Outlet
kWHP0.7 MPa0.8 MPa1.0 MPa
OFD-200W20026833.533.429.985±33150×2200×22004500DN100
OFD-220W22029536.035.933.385±33150×2200×22005000DN100
OFD-250W25033542.942.738.385±33150×2200×22005200DN100
OFD-280W28037546.845.742.785±33450×2450×22006400DN100
OFD-315W31542251.551.346.890±33450×2450×22006600DN100
OFD-355W35547658.557.951.090±33450×2450×22006800DN100

* All 14 OFD models verified against master spec sheet. "A" = Air-Cooled, "W" = Water-Cooled. ISO 8573-1 Class 0 certified. Specifications subject to change. Contact ZIQI for exact configuration and pricing.

Frequently Asked Questions

What does ISO 8573-1 Class 0 mean?
Class 0 is the most stringent air quality standard under ISO 8573-1. It guarantees 100% oil-free air with zero risk of contamination — essential for food, pharmaceutical, electronics, and chemical manufacturing where even trace oil can ruin products or pose safety risks.
Why use stainless steel rotors in the 2nd stage?
In dry compression without oil lubrication, humidity in the intake air can cause corrosion. ZIQI uses stainless steel for the 2nd stage (high-pressure) rotors to prevent rust, ensuring air purity and extending air end lifespan even in humid tropical environments.
What is Ultracoat technology?
Ultracoat is a proprietary rotor coating made of Teflon (PTFE) and Molybdenum Disulfide (MoS₂). It provides dry lubrication between rotors without oil, reduces internal leakage for higher efficiency, resists high temperatures, and lasts the lifetime of the machine.
Do dry oil-free compressors need oil separator filters?
No. Since no oil enters the compression chamber, there is no need for oil separators, oil filters, or condensate treatment. This eliminates pressure drop across filters, reduces maintenance costs, and produces clean condensate that can be directly discharged.
How does dry oil-free compare to water-lubricated oil-free?
Dry oil-free (OFD) uses no liquid in the compression chamber — only coated rotors with tight clearances. Water-lubricated (OFW) injects purified water for sealing and cooling. OFD is better for high-temperature environments and applications requiring zero liquid contact. OFW is quieter and more energy-efficient but requires water treatment.
What is the maintenance interval for dry screw compressors?
Air end coating and bearings typically require inspection at 40,000-60,000 hours. Air intake filters should be changed every 2,000-4,000 hours. Since there is no oil circuit, there are no oil changes, no oil filters, and no separator elements — significantly reducing routine maintenance.
Can the OFD series work in tropical or high-humidity environments?
Yes. The stainless steel 2nd stage rotors and Ultracoat coating are specifically designed for corrosion resistance. Air-cooled models (45-185 kW) work well in most environments. For ambient temperatures above 40°C or high-humidity installations, water-cooled models (200-355 kW) are recommended.
What industries typically use dry oil-free compressors?
Primary industries include pharmaceutical manufacturing (GMP/FDA compliance), food and beverage processing, semiconductor and electronics fabrication, chemical processing, textile manufacturing, hospital and medical air systems, and any application where oil contamination poses product quality or safety risks.

Related Products

Request a Class 0 Oil-Free Proposal

Tell us your air quality requirement, flow demand, and operating environment — we'll recommend the optimal OFD configuration.

Basic Information
  • Year Established
    --
  • Business Type
    --
  • Country / Region
    --
  • Main Industry
    --
  • Main Products
    --
  • Enterprise Legal Person
    --
  • Total Employees
    --
  • Annual Output Value
    --
  • Export Market
    --
  • Cooperated Customers
    --
ZIQI OFD Dry Oil-Free Compressor Specs
Model Dry Oil-FreeAir Delivery (m³/min) @ PressureMotor PowerNoise
dB(A)
Dimension (mm)Weight
(kg)
Outlet
0.7 MPa0.8 MPa1.0 MPakWHPLWH
OFD-45A7.66.66.4456080±32150155018402400DN50
OFD-55A9.29.18.0557380±32150155018402600DN50
OFD-75A12.611.610.97510080±32350165018402800DN50
OFD-90A13.413.312.59012080±32350165018403400DN50
OFD-110A20.018.816.411014782±32850185019103400DN65
OFD-132A23.622.219.913217782±32850185019103450DN65
OFD-160A26.925.523.616021482±32850185019103550DN65
OFD-185A29.829.726.818524882±32850185019103950DN65

Recommended

Send your inquiry

GET IN TOUCH WITH US

Just leave your email or phone number on the contact form so we can serve you.

Chat
Now

Send your inquiry

Choose a different language
╳
العربية
Беларуская
Deutsch
Ελληνικά
English
Español
français
Magyar
italiano
Nederlands
Português
русский
Current language:English