ENERGY SAVING CASES
VR

Energy-saving reform project of Shanghai XXX Vacuum Electronics Co., LTD.

The energy-saving reform project of Shanghai XXX Vacuum Electronics Co., LTD.used two sets others brand air compressor before the transformation.,In the later stage, the compressed air consumption was not enough.After learned about the customers air demand, ZIQI company formulated the scheme of using one set double-stage variable speed screw air compressor GAT-110ACFV and one set blower type adsorption air dryer(zero air loss) to replace the 2 sets others brand air compressors.


On-site photos of the customer's air compressor room before the renovation:

Photos of the customers on-site air compressor room after installation:

 

Compressor Model:V-90-8A、V-55-8;

Data before renovation(2023.5.10~18):

Date

Operating time

h

Electricity consumptionV-90-8A

kW·h

Electricity consumptionV-55-8

kW·h

Data of flow meter

Nm³

Air consumption

Nm³

Total

kW·h

May 10th

4.5

430

11.2

1579.48

1579.48

441.2

May 11th

11

988.8

14.8

5432.98

3853.5

1003.6

May 12th

4.5

414.4

0.4

7128.88

1695.9

414.8

May 15th

10

784.4

31.2

12426.5

5297.62

815.6

May 16th

14

1243.6

82.4

17834.7

5408.2

1326

May 17th

17

1504

133.6

26729.6

8894.9

1637.6

May 18th

14.5

1285.2

259.6

35181.67

8452.07

1544.8


Data after renovation(2023.5.10~18):

Field data

Baseline total air production

Baseline Total Power Consumption

35181.67 Nm³

7183.6 kW·h

Energy Benchmark

Baseline power consumption=total power consumption/total air production(unit kW·h/ Nm³):0.204 kW·h/Nm³

 

Compressor Model:GAT-110A CFV

Data before renovation(2023.7.24~28):

Date

Ammeter 1

Flow meter data

Total air consumption

Total power consumption

Baseline power consumption

July 24th

1418.77

316907.68

 

 

 

July 25th

1434.33

322748.07

5840.39

622.40

0.107

July 26th

1445.25

326376.1

3628.03

436.80

0.120

July 27th

1457.88

330027.37

3651.27

505.20

0.138

July 28th

1485.63

338090.77

8063.40

1110.00

0.138

Data before renovation(2023.7.24~28):

Field data

Baseline total air production

Baseline Total Power Consumption

21183.09 Nm³

2674.40 kW·h

Energy Benchmark

Baseline power consumption=total power consumption/total air production(unit kW·h/ Nm³):0.126 kW·h/Nm³

 

Baseline electricity consumption:

(0.204-0.126)/0.204=38.24%

It can be concluded that the Baseline electricity consumption of GAT-110A CFV is 38.24% higher than V-90-8A、V-55-8’s.

The calculation of energy saving per month:

GAT-110ACFV:110KW×8h/day×30days/month×38.24%=10095 kw/month

After renovation,the data of energy saving is approximately 121,140 kw h per year.

Basic Information
  • Year Established
    --
  • Business Type
    --
  • Country / Region
    --
  • Main Industry
    --
  • Main Products
    --
  • Enterprise Legal Person
    --
  • Total Employees
    --
  • Annual Output Value
    --
  • Export Market
    --
  • Cooperated Customers
    --
Chat
Now

Send your inquiry

Choose a different language
العربية
Беларуская
Deutsch
Ελληνικά
English
Español
français
Magyar
italiano
Nederlands
Português
русский
Current language:English