A screw compressor tripping the breaker or shutting down abruptly is a self-preservation mechanism. The machine is actively protecting itself from catastrophic electrical or mechanical destruction. While high-temperature shutdowns are well understood, "tripping" — specifically when the main breaker or thermal overload relay disconnects the power — points to a completely different set of problems common in industrial compressed air systems.
An electrical trip means the motor is drawing too much current (amperage). The standard checklist covers incoming voltage and loose wires. But they often miss the root cause behind chronic, mysterious overloads: mechanical binding inside the air end masquerading as an electrical fault.
This guide covers all seven root causes of screw compressor tripping in diagnostic order — separating the simple electrical fixes from the critical mechanical failures.
Before opening the electrical cabinet, look at the PLC controller. A compressor "trip" falls into one of four distinct protection categories. Knowing which one triggered the shutdown dictates your entire diagnostic path.
| Fault Type | Typical PLC Message | What It Means |
|---|---|---|
| Electrical Overload | "Motor Overload" / "Main Motor Curr High" | The motor is working too hard. Current exceeded the thermal relay setting. Check voltage or mechanical friction. |
| Power Supply Fault | "Phase Sequence" / "Phase Failure" | Incoming grid power is flawed. Missing a phase or wired backward. Trips instantly at startup. |
| Pressure Overload | "Discharge Pressure High" | Air cannot escape the system. Usually a blocked separator or closed discharge valve forcing the motor to stall. |
| Thermal Fault | "Discharge Temp High" | Cooling issue (oil, cooler, fan). The motor is fine, but the compression cycle is too hot. |
Ranked from the most common external faults to the most severe internal mechanical failures.
Electric motors rely on a steady voltage to generate torque. If the incoming facility voltage drops (brownout), the motor must draw more amperage to maintain the same power output. When the amperage crosses the breaker's limit, it trips.
Similarly, a voltage imbalance of just 3% between the three phases (L1, L2, L3) causes the motor to run 20% hotter, triggering the overload relay.
The oil separator removes oil from the compressed air before it exits the machine. If this filter becomes clogged with degraded oil sludge or dirt, it creates a massive restriction.
The air end continues pumping air into the vessel, but the air cannot escape. Internal pressure spikes drastically (often exceeding 12 or 13 bar on an 8 bar machine). The motor requires immense torque to overcome this backpressure, spiking the amperage and tripping the breaker.
A screw compressor is designed to start unloaded (intake valve closed) to allow the motor to reach full speed before it begins doing the heavy work of compressing air.
If the intake valve is jammed open, or the minimum pressure valve is stuck, the motor tries to start while already fighting against internal system pressure. This requires a massive starting torque that standard starters cannot handle, resulting in an instant trip within 5 seconds of pressing start.
Industrial compressors vibrate. Over thousands of hours, the heavy-duty power cables connected to the main contactors can vibrate loose. A loose connection increases electrical resistance, which generates heat and causes localized voltage drops.
Furthermore, the internal contacts of the main AC contactors arc slightly every time the machine starts. Over time, these contacts pit and burn, increasing resistance and falsely tripping the thermal overload relay.
Screw air ends must never run in reverse. If they do, the rotors will pull a vacuum, denying themselves oil lubrication, and will weld together from friction within seconds.
If the factory power grid drops one phase, or if an electrician accidentally swaps two wires during maintenance, the phase protection relay detects the fault and trips the machine instantly to prevent catastrophic reverse rotation or single-phase motor burnout.
In an oil-injected compressor, the oil doesn't just cool; it acts as a fluid seal and lubricant between the tightly meshed rotors. If oil flow is restricted (due to a faulty thermal bypass valve, a clogged oil filter, or running dry), the rotors lose their lubricating film.
Without oil, metal-on-metal friction increases exponentially. The motor draws massive current trying to force the dry rotors to turn, quickly hitting the overload trip point.
When a compressor trips, do not just press the reset button. Follow this logical sequence to isolate the fault safely.
Tripping incidents cause unplanned downtime and stress the electrical components of the compressor. The best approach is prevention through maintenance and proper specification.
| Failure Point | Preventative Action | Frequency |
|---|---|---|
| Electrical Connections | Thermal imaging of electrical cabinet; re-torque terminals | Every 6 Months |
| Oil Separator | Replace element; monitor differential pressure | Every 3,000–4,000 Hours |
| Intake Valve | Inspect cylinder and springs; replace rebuild kit | Every 8,000 Hours |
| Air End Bearings | Vibration analysis; strict adherence to oil change intervals | Vibration checks annually; Overhaul at 40,000 Hrs |
| Overall System | Implement a structured preventative maintenance schedule | |
Many tripping issues stem from using inadequate components. Specifying compressors with oversized motors, premium switchgear (Schneider Electric or Siemens), and robust German airends significantly reduces the risk of overload conditions.