ZIQI Compressor For Global Energy Saving, Welcome To Contact Us.
008615026767628

Compressed Air Systems Engineer
ZIQI Compressor Group · Updated June 2026
When a screw compressor fails to start completely, the root causes are concentrated within three physical dimensions: Electrical Faults (tripped main breakers, severe phase loss, blown control fuses, or burnt contactor coils); Control System Faults (unreset E-stop buttons, uncleared historical PLC fault codes, or extreme sensor drift); and Mechanical Faults (high static back pressure trapped in the separator tank, or a physically seized air end rotor). Most of these faults can be isolated and cleared within 30 minutes following standard procedures.
When you prepare for the first production shift of the morning, a dead screw compressor is your worst nightmare. You press the start button, and the machine either remains completely unresponsive or trips the breaker instantly, bringing your entire production line to a halt. As a leading screw air compressor manufacturer, ZIQI understands the severe urgency of this unexpected downtime. This guide focuses strictly on "static startup failures" (when the machine absolutely won't turn on), differentiating it from operational tripping. By following this troubleshooting framework, operators and maintenance engineers can accurately isolate the root cause across electrical, control, or mechanical systems, resolving over 70% of common startup faults without needing to wait for external service technicians.
Facing a dead compressor, blindly pressing the start button repeatedly or forcing a breaker reset is extremely dangerous and can cause secondary electrical fires or mechanical destruction. You must categorize the physical symptoms first. Follow this 3-step rapid diagnosis logic developed by the ZIQI Dynamics Lab:
Step 1: Check the PLC Display Panel (Determine Control & Main Power Baseline)
Completely Blank Display: If the PLC screen and indicators are entirely dark, the fault is 100% on the power supply side. Immediately check the external incoming line voltage, the main circuit breaker (MCCB), and the secondary fuses in the control circuit.
Display is On with Active Fault Codes/Red Lights: The control circuit has power. Do not force a start. Read the text prompt (e.g., "Emergency Stop", "Motor Overload", "High Temp"). The control system is actively executing a safety interlock.
Display is On, No Faults, but Unresponsive to Start Button: The control logic is issuing the start command, but the physical execution circuit is open. Focus on the start button's internal contacts, PLC output relays, or an open main contactor coil.
Step 2: Listen for Acoustic Feedback During the Start Attempt (Catch Mechanical Signs)
Loud Electromagnetic "Humming" Noise but No Rotation: Followed by a breaker trip or thermal relay activation within 1-3 seconds. This is a high-risk symptom indicating the motor is energized but lacks driving torque. It points with high confidence to phase loss, a jammed contactor before Y-Δ transition, or a physically locked air end rotor.
Absolute Silence Inside the Cabinet: Current is not reaching the contactor coils at all. The main control loop is physically broken. Focus on control wiring and intermediate relay contacts.
Step 3: Analyze the Timing Context (Differentiate Sudden vs. Initial Setup Faults)
Fails to Start on Initial Commissioning or After Rewiring: Prioritize checking for phase sequence reversal (causing phase relay protection) or parameter mismatches where pressure/temp limits don't align with physical sensor ranges.
Sudden Morning Failure on a Normally Running Machine: A 90% probability points to an uncleared protection trip (from overnight voltage spikes), extreme oil viscosity due to low ambient temperatures causing high static resistance, or residual static back pressure from an improperly closed discharge valve during the last shutdown.
To assist technicians in precise quantitative troubleshooting, the table below categorizes the 9 core reasons for a startup failure, their exact symptoms, and rapid on-site verification methods using standard tools:
| # | Category | Cause | Symptoms | Quick Check |
|---|---|---|---|---|
| 1 | Electrical | Main Circuit Breaker (MCCB) Tripped | PLC is completely dead, and the main switch handle in the cabinet is sitting in the middle "Trip" position. | Use a multimeter to measure the incoming 3-phase line voltage at the breaker terminals (e.g., 380V/415V). |
| 2 | Electrical | Phase Loss / Severe Voltage Imbalance | Emits a heavy hum on start attempt and trips instantly; phase sequence relay shows a red alarm. | Measure AC line voltages between phases. An imbalance exceeding ±5% will trigger safety protections. |
| 3 | Electrical | Control Transformer Fuse Blown | Main power is on and breaker is closed, but the PLC and 24V/110V control circuits are entirely dead. | With power off, use a multimeter (continuity mode) across the fuse. Infinite resistance means it is blown. |
| 4 | Electrical | Contactor Coil Burnt / Contacts Welded | Hear a faint click when pressing start, but the main contactor doesn't pull in, or contacts are blackened. | Measure resistance across A1-A2 coil terminals. Should be tens to hundreds of ohms. Zero or infinite means damaged. |
| 5 | Control | Emergency Stop (E-stop) Not Reset | PLC screen is backlit but forcibly displays "Emergency Stop" or related alarm code. | Visually inspect and twist the red E-stop button clockwise to pop it out, then press "Clear" on the panel. |
| 6 | Control | Previous Fault Codes Not Cleared | Start button unresponsive; panel continuously flashes a historical high temp (>105°C) or overload error. | Enter the PLC parameter menu, input the operator password, and manually execute a fault "Reset" or "Clear". |
| 7 | Control | Startup Conditions Not Met (Sensor Error) | No obvious alarms, but the static pressure reads >0.2 MPa or temperature shows an extreme -5°C while off. | Observe sensor readings while the machine is off. Severe deviation from atmospheric pressure/ambient temp indicates sensor drift. |
| 8 | Mechanical | High Static Back Pressure | Motor turns heavily for half a second then trips on overload. Separator tank gauge shows high pressure. | Check the analog pressure gauge on the air/oil tank. If residual pressure >0.15 MPa, the blow-down valve is stuck. |
| 9 | Mechanical | Motor Overload / Thermal Relay Tripped | PLC displays "Motor Overload", and the mechanical reset rod on the thermal relay inside the cabinet is popped up. | With power off, try to manually rotate the main motor cooling fan or coupling. Confirm the air end isn't physically jammed. |
Once the specific fault is isolated, site engineers can execute these standardized corrective actions:
Fixing a Tripped Breaker: Never force a blind reset. Measure phase-to-phase and phase-to-ground insulation resistance first. If clear of hard shorts, push the breaker handle firmly down to the Reset position, then up to ON. If it trips immediately upon closing, a hard short exists in the motor windings.
Fixing Phase Loss: Check upstream distribution cabinet fuses and inspect wire terminals for loose, oxidized connections caused by thermal expansion. Retorque all terminals to spec. If the grid is missing a phase, contact the utility provider immediately.
Fixing Blown Control Fuses: Never bypass with copper wire. Investigate the secondary circuit for shorts to ground (e.g., a burnt solenoid coil). Once the short is cleared, replace with a fast-blow ceramic fuse of the exact same amperage.
Fixing Faulty Contactors: If contacts show minor carbon buildup, clean with fine sandpaper. If the coil is open-circuit or contacts are physically welded, replace the entire contactor with an identical AC-3 rated unit.
Fixing Unreset E-Stop: Firmly twist the red E-stop knob clockwise until spring tension pops it out. Then, press the "Fault Reset" or "Clear" button on the main PLC interface to refresh the underlying logic.
Clearing Historical Faults: After resolving the physical cause of a previous overload or high temp, enter the main system menu, input the operator password, and execute the "Clear Fault Log" command to release the software lock.
Fixing Sensor Errors: If static pressure reads >0.05 MPa deviation, perform a zero-point calibration. If calibration fails or the temp sensor shows extreme open/short values (-20°C / 150°C), replace the damaged Pt100/Pt1000 RTD sensor.
Releasing Static Back Pressure: Manually open the pressure relief valve to bleed the oil tank down to 0 MPa. Disassemble the blow-down solenoid valve to check for broken springs or carbonized oil jamming the spool.
Resetting Motor Overload: Wait 5 minutes for the thermal bimetallic strips to cool naturally, then press the red/blue mechanical "Reset" button. Use a large pipe wrench to manually rotate the air end coupling 2-3 turns to ensure it is not seized.
⚠️ DANGER: When to Stop DIY Checks and Call an Expert
While 70% of startup faults can be resolved using this guide, encountering the following extreme symptoms indicates severe hardware damage or arc flash risks. Do not re-energize the system. Contact ZIQI service engineers immediately:
Immediate Re-trip After Reset: If the breaker trips again with an aggressive arc flash or loud pop the instant you press start after a reset. This confirms a dead short to ground in the motor, VSD inverter module, or main cables.
Acrid Burning Smells & Charring: Obvious physical smells of burnt insulating varnish coming from the cabinet, blackened contactor housings, or melted copper busbars.
Violent Metallic Grinding on Start: If pressing start results in severe metal-on-metal clunking inside the air end and current spikes to 3x rated amps. This points to shattered bearings or a locked rotor; forcing it will destroy the screw element.
Severe Dynamic Voltage Drop: Static voltage is fine, but during the startup surge, one phase drops by more than 15%. This requires a certified electrical engineer to assess grid capacity and transformer winding integrity.
To reduce startup failure rates below 0.5%, implement a scientific preventive maintenance regime. The table below outlines the high-standard electrical and control checks recommended by ZIQI Quality Control:
| Frequency | Mandatory Maintenance Task |
|---|---|
| Daily | Before the first shift, verify PLC panel static temperature and pressure readings, confirm the oil tank gauge is at absolute zero, and check for unreset warning lights. |
| Monthly | Disconnect main power and use dry, low-pressure air to blow conductive dust out of the control cabinet, VSD heatsinks, and contactor surfaces. Inspect contactor contacts for deep pitting. |
| Quarterly | Use an infrared thermometer on breakers and terminals under load to detect hot spots. Retorque all bolts to eliminate contact resistance. Megger test the motor's static insulation resistance. |
| Annually | Execute mandatory preventive replacement: swap aging control transformer fuses, replace main contactors nearing electrical lifespan limits, and calibrate pressure/temperature sensors against standard meters. |
Immediate tripping is generally caused by two extreme mechanisms. First, an electrical hard short or severe overcurrent, such as a phase-to-phase motor winding short or a blown IGBT module in the VSD, triggering instantaneous magnetic breaker tripping. Second, extreme mechanical resistance. If residual pressure in the oil tank exceeds 0.15 MPa, or freezing ambient temps make the oil overly viscous, the rotors face massive resistance during the star-delta transition, spiking current and popping the thermal overload relay.
A heavy electromagnetic hum without rotation means the stator has established a static magnetic field, but lacks the rotating field or torque to overcome load resistance. The core causes are highly specific: single-phasing of the main power supply (running on only two phases), or a mechanically locked air end rotor due to carbonized oil from a previous high-temperature shutdown. Disconnect power immediately to prevent the windings from burning out within seconds.
Resetting requires dual initialization (hardware and software). First, eliminate the physical trigger (e.g., clean coolers for a high temp fault). Second, if a thermal relay tripped, open the cabinet, wait 5 minutes for it to cool, and physically push the mechanical reset rod. Finally, press "Fault Reset" on the PLC interface or enter the password to clear the software lock. The machine is only ready when the status reads "Ready to Start" or "Standby".
Absolutely. The starting torque of an AC induction motor is proportional to the square of the input voltage. If a nominal 380V grid drops heavily to 330V during the startup surge, actual starting torque drops to roughly 75% of its rating. The motor simply cannot overcome the static friction and compression resistance of the air end, preventing RPMs from climbing and failing the Y-Δ transition, leading to an overload shutdown.
Static back pressure is residual compressed air trapped inside the air/oil separator, compression chamber, and internal piping while the machine is off. Normally, a blow-down valve vents this pressure below 0.02 MPa within 30 seconds of shutdown to allow an unloaded restart. If this valve jams, the rotors must aggressively compress against pre-existing high-pressure gas at low startup RPMs, creating massive reverse torque that instantly overloads the motor.
Perform a three-step electrical test. First, with power off, inspect the contacts. Massive blackening, pitting, or physically welded/melted silver alloy contacts confirm failure. Second, measure the A1-A2 control coil resistance; 0 ohms (shorted) or infinite ohms (burnt open) means it's dead. Third, if energized and it emits a violently loud, chattering metallic vibration, the iron core is rusted or oily, causing poor contact that will eventually burn out the motor.
If the fault indicator remains locked after following these standard steps, or an unknown hex code appears, do not attempt further forced starts. Send us your fault code details, a clear photo of the PLC display, and your live voltage readings. ZIQI's senior engineering team will provide remote, expert-level diagnostics promptly to get your plant back on track.
Copyright © 2026 ZIQI Compressor (Shanghai) Co., Ltd - All rights reserved.